Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Electrical stimulation induces synaptic changes in the peripheral auditory system.

Qiang Li | Tianhao Lu | Chen Zhang | Marlan R Hansen | Shufeng Li
The Journal of comparative neurology | 2020

Since a rapidly increasing number of neurostimulation devices are used clinically to modulate specific neural functions, the impact of electrical stimulation on targeted neural structure and function has become a key issue. In particular, the specific effect of electrical stimulation via a cochlear implant (CI) on inner hair cell (IHC) synapses remains unclear. Importantly, CI candidacy has recently expanded to include patients with partial hearing loss. Unfortunately, some CI recipients experience progressive hearing loss after activation of electrical stimulation. The mechanism(s) accounting for loss of residual hearing following electrical stimulation is unknown. Here normal-hearing guinea pigs were implanted with customized CIs. Intracochlear electrical stimulation with an intensity equal to or above electrically evoked compound action potential (ECAP) threshold decreased the excitability of auditory nerve. Furthermore, the number of synapses between IHCs and the afferent spiral ganglion neurons (SGNs) also decreased after electrical stimulation with higher intensities. However, no significant change was observed in the packing density and perikaryal area of SGNs as well as the quantity of hair cells. These results carry important implications for use of CIs in patients with residual hearing and for an increasing number of patients treated with other neurostimulation devices. Notably, the results were based on acute electrical stimulation. Considering the complex interaction between CIs and targeted tissues, it is urgent to conduct further research to clarify whether the similar changes could be induced by chronic electrical stimulation.

Pubmed ID: 31658367

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.