Improving the accuracy of digital templating: achieving success through stakeholder management.

Hammad Parwaiz | Boris Aliaga Crespo | Joshua Filer | Ashley Thorpe | Rosie Seatter | Dominique Suzanne Faulkner | Harvey Sandhu
BMJ open quality | 2019

The use of a marker ball in digital templating for hip arthroplasty is a well-established method of preoperative planning and is used to overcome the inherent magnification in plain film radiographs. Our hospital policy is to place a marker ball in all anteroposterior pelvic films taken in the emergency department (ED) which have been requested for suspected neck of femur fractures. We carried out a baseline measurement followed by three Plan-Do-Study-Act cycles for all pelvic films taken in ED during July 2016, November 2016, February 2017 and November 2017. Interventions between the baseline measurement and cycle 1 were to educate the lead radiographer and publish the results in the radiology newsletter, and between cycles 1 and 2 was to run a teaching session for radiographers, display posters in the X-ray department and place an electronic prompt on the X-ray machine to alert them of the need to place a marker ball in the X-ray field. Cycle 3 looked to see if improvements were sustained. 16/81 (20%) radiographs complied with the policy in our baseline measurement; 25/51 (46%, p=0.002) in cycle 1; 40/54 (74%, p=0.0056) in cycle 2; and 48/63 (76%) in cycle 3. Our quality improvement project led to large improvements in clinical practice through straightforward, small, but appropriately targeted interventions. Stakeholder management is key to successfully implementing change. The next step is to switch from the VoyantMark to the KingMark marker ball, as it has greater accuracy of templating and is also easier to place within the field of an X-ray.

Pubmed ID: 31259274

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


GraphPad Prism (tool)

RRID:SCR_002798

Statistical analysis software that combines scientific graphing, comprehensive curve fitting (nonlinear regression), understandable statistics, and data organization. Designed for biological research applications in pharmacology, physiology, and other biological fields for data analysis, hypothesis testing, and modeling.

View all literature mentions