Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Preliminary evaluation of 18F‑AlF‑NOTA‑MAL‑Cys40‑Exendin‑4 in rodent heart after myocardial ischemia and reperfusion.

Xietian Pan | Qing Xu | Jiangwei Chen | Tingting Wang | Mingming Zhang | Haichang Wang | Haokao Gao
Molecular medicine reports | 2019

Glucagon‑like peptide‑1 (GLP‑1) and its receptor (GLP‑1R) exert cardioprotective effects after myocardial ischemia and reperfusion (MI/R) in animal models and human clinical trials. Receptor imaging with positron emission tomography (PET) provides a non‑invasive method for monitoring GLP‑1R expression. In the present study, a fluorine‑18‑labeled aluminum fluoride exendin‑4 analog [18F‑AlF conjugated with 1,4,7‑triazacyclononanetriacetic acid (NOTA)‑maleimide (MAL)‑Cys40‑exendin‑4] was synthesized and evaluated in a rat MI/R model for GLP‑1R imaging. NOTA‑MAL‑Cys40‑exendin‑4 was synthesized by coupling Cys40‑exendin‑4 with NOTA‑MAL. NOTA‑MAL‑Cys40‑exendin‑4 was then conjugated with 18F‑AlF to obtain 18F‑AlF‑NOTA‑MAL‑Cys40‑exendin‑4. The yield of 18F‑AlF‑NOTA‑MAL‑Cys40‑exendin‑4 was 18.5±3.4% (not decay corrected). The process was completed within ~30 min. In rat MI/R models, the tracer exhibited specific binding to GLP‑1R and an appropriate signal‑to‑noise ratio. At 8 h post‑MI/R, tracer uptake reached its peak [0.35±0.053% of injected dose (%ID)/g; n=6] in ischemic myocardium. Localized tracer uptake decreased 1 day (0.20±0.032 %ID/g; n=6) and 3 days (0.16±0.017 %ID/g; n=6) post‑MI/R compared with 8 h post‑MI/R, but still remained higher compared with sham‑operated groups (0.06±0.012 %ID/g; n=6). Pre‑injected unlabeled exendin‑4 effectively blocked tracer accumulation (0.09±0.041 %ID/g; n=6). In conclusion, 18F‑AlF‑NOTA‑MAL‑Cys40‑exendin‑4 demonstrated favorable characteristics for GLP‑1R imaging following MI/R. PET imaging using 18F‑AlF‑NOTA‑MAL‑Cys40‑exendin‑4 in rodent hearts after MI/R revealed a dynamic pattern of GLP‑1R upregulation.

Pubmed ID: 31257516

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Abcam (tool)

RRID:SCR_012931

A commercial antibody supplier which supplies primary and secondary antibodies, biochemicals, proteins, peptides, lysates, immunoassays and other kits.

View all literature mentions

SD (tool)

RRID:RGD_70508

Rattus norvegicus with name SD from RGD.

View all literature mentions