Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Dynamics of the accommodative response under artificially-induced aniseikonia.

Raimundo Jiménez | Rubén Molina | Carla Jiménez | José Ramón Jiménez | Beatriz Redondo | Jesús Vera
Experimental eye research | 2019

Aniseikonia has demonstrated to deteriorate the binocular function, however its impact on the accommodative response remains unknown. The present study aimed to analyze the effects of artificially-induced aniseikonia, using afocal magnifiers, on the dynamics of the accommodative response. The magnitude and variability of the accommodative response were objectively measured in 20 young healthy subjects by a binocular open-field autorefractometer. Participants observed a static stimulus for 90 s, under seven degrees of aniseikonia (0%, 1%, 3%, 5%, 8%, 10% and 12%), and at three distances (500 cm, 40 cm and 20 cm). Complementarily, near stereoacuity, and perceived levels of fatigue and visual discomfort were assessed. The degree of induced aniseikonia was associated with the magnitude of the accommodative response (p < 0.001, ηp2 = 0.329), obtaining a statistically significant reduced accommodative lag for the induced aniseikonia conditions of 8%, 10% and 12% in comparison to the control condition at 40 cm (p-corrected = 0.019, <0.001 and 0.013, respectively) and at 20 cm (p-corrected < 0.001, <0.001 and 0.003, respectively). However, the degree of induced aniseikonia did not reveal any effect on the variability of accommodation (p > 0.05). We also found a decline in near stereoacuity and an increment of visual symptomatology when inducing aniseikonia (p < 0.05). Our data evidenced that greater degrees of induced aniseikonia cause a heightened accommodative response. These preliminary findings may be of relevance for patients undergoing cataract or refractive surgery procedures in which aniseikonia can be induced.

Pubmed ID: 31132345

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


JASP (tool)

RRID:SCR_015823

Statistics software that performs common frequentist analyses and Bayesian analyses. It conducts ANOVA, linear regression, and correlation, among other statistical tests.

View all literature mentions