Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Soluble triggering receptor expressed on myeloid cells-1 as a useful biomarker for diagnosing ventilator-associated pneumonia after congenital cardiac surgery in children.

Chunxiang Li | Limin Zhu | Xiaolei Gong | Zhuoming Xu | Yujie Liu | Mingjie Zhang | Qing Cao
Experimental and therapeutic medicine | 2019

The present study aimed to assess the usefulness of soluble triggering receptor expressed on myeloid cells 1 (sTREM-1) in the diagnosis of ventilator-associated pneumonia (VAP) in paediatric patients with congenital heart disease (CHD) following cardiac surgery. The current prospective study enrolled 48 patients with congenital heart diseases who were suspected of having VAP; these patients were undergoing cardiac surgery between August 2016 and October 2017 in the Cardiac Intensive Care Unit of Shanghai Children's Medical Center (Shanghai, China). A total of 31 patients were diagnosed with VAP using a polymerase chain reaction (PCR) assay, while 17 patients without VAP were designated as the Non-VAP group. A bronchoscopy was performed and samples were collected for measurement on the day that VAP was diagnosed. The sTREM-1 levels were measured in bronchoalveolar lavage fluid (BALF) and exhaled ventilator condensate (EVC). BALF specimens were also sent to the microbiology laboratory for PCR assays and quantitative culturing. The positive detection rate of bacteria using the PCR assay and traditional culture was 64.6% (31/48) and 39.6% (19/48). sTREM-1 was significantly higher in the BALF (146.21 pg/ml vs. 118.06 pg/ml) and EVC (125.29 pg/ml vs. 120.48 pg/ml) of patients with VAP demonstrated compared with the patients without VAP. The findings suggest that the detection of sTREM-1 in BALF and EVC samples may be useful for the diagnosis of VAP following heart surgery in children.

Pubmed ID: 30651775

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


MedCalc (tool)

RRID:SCR_015044

Statistical software for ROC curve analysis. MedCalc performs several statistical tests such as method comparison, method evaluation, reference intervals, and meta-analysis.

View all literature mentions