Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

LocZ is a new cell division protein involved in proper septum placement in Streptococcus pneumoniae.

Nela Holečková | Linda Doubravová | Orietta Massidda | Virginie Molle | Karolína Buriánková | Oldřich Benada | Olga Kofroňová | Aleš Ulrych | Pavel Branny
mBio | 2014

How bacteria control proper septum placement at midcell, to guarantee the generation of identical daughter cells, is still largely unknown. Although different systems involved in the selection of the division site have been described in selected species, these do not appear to be widely conserved. Here, we report that LocZ (Spr0334), a newly identified cell division protein, is involved in proper septum placement in Streptococcus pneumoniae. We show that locZ is not essential but that its deletion results in cell division defects and shape deformation, causing cells to divide asymmetrically and generate unequally sized, occasionally anucleated, daughter cells. LocZ has a unique localization profile. It arrives early at midcell, before FtsZ and FtsA, and leaves the septum early, apparently moving along with the equatorial rings that mark the future division sites. Consistently, cells lacking LocZ also show misplacement of the Z-ring, suggesting that it could act as a positive regulator to determine septum placement. LocZ was identified as a substrate of the Ser/Thr protein kinase StkP, which regulates cell division in S. pneumoniae. Interestingly, homologues of LocZ are found only in streptococci, lactococci, and enterococci, indicating that this close phylogenetically related group of bacteria evolved a specific solution to spatially regulate cell division.

Pubmed ID: 25550321

Research resources used in this publication

None found

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


MicrobeTracker (tool)

RRID:SCR_015939

THIS RESOURCE IS NO LONGER IN SERVICE, documented May 10, 2017. A pilot effort that has developed a centralized, web-based biospecimen locator that presents biospecimens collected and stored at participating Arizona hospitals and biospecimen banks, which are available for acquisition and use by researchers. Researchers may use this site to browse, search and request biospecimens to use in qualified studies. The development of the ABL was guided by the Arizona Biospecimen Consortium (ABC), a consortium of hospitals and medical centers in the Phoenix area, and is now being piloted by this Consortium under the direction of ABRC. You may browse by type (cells, fluid, molecular, tissue) or disease. Common data elements decided by the ABC Standards Committee, based on data elements on the National Cancer Institute''s (NCI''s) Common Biorepository Model (CBM), are displayed. These describe the minimum set of data elements that the NCI determined were most important for a researcher to see about a biospecimen. The ABL currently does not display information on whether or not clinical data is available to accompany the biospecimens. However, a requester has the ability to solicit clinical data in the request. Once a request is approved, the biospecimen provider will contact the requester to discuss the request (and the requester''s questions) before finalizing the invoice and shipment. The ABL is available to the public to browse. In order to request biospecimens from the ABL, the researcher will be required to submit the requested required information. Upon submission of the information, shipment of the requested biospecimen(s) will be dependent on the scientific and institutional review approval. Account required. Registration is open to everyone. Software for bacterial microscopy image analysis. It is designed to detect and outline bacterial cells in microscopy images and to analyze fluorescence signal inside them.

View all literature mentions

Olympus FluoView 300 Confocal Microscope (tool)

RRID:SCR_020345

Confocal microscopy can improve conventional fluorescence images by recording fluorescence generated from the focal plane within the sample, while rejecting all other light coming from above or below the focal plane. The efficient point-scan/pinhole-detection confocal optics of the FluoView systems virtually eliminate out of focus light to produce high-contrast images with superb resolution. The FluoView systems are fully integrated workstations that incorporate user-friendly image acquisition and image analysis software with high-resolution confocal optics that require no user alignment. An , Windows-based graphic user interface allows new users to quickly generate images in various scan modes, such as XY, XZ, XT, XYZ, XYT, and XYZT. Standard image formats, including TIFF and AVI, permit easy, direct export of FluoView images to off-line analysis packages. XY scanning is performed with a pair of galvanometric mirrors, yielding a wide scanning range to cover up to a field number of 20. The optical zoom (up to 10x magnification) can be performed by narrowing the scanning range while maintaining the maximum pixel resolution of up to 2048 x 2048 pixels.

View all literature mentions

Olympus FluoView 300 Confocal Microscope (tool)

RRID:SCR_020339

Confocal microscopy can improve conventional fluorescence images by recording fluorescence generated from the focal plane within the sample, while rejecting all other light coming from above or below the focal plane. The efficient point-scan/pinhole-detection confocal optics of the FluoView systems virtually eliminate out of focus light to produce high-contrast images with superb resolution. The FluoView systems are fully integrated workstations that incorporate user-friendly image acquisition and image analysis software with high-resolution confocal optics that require no user alignment. An , Windows-based graphic user interface allows new users to quickly generate images in various scan modes, such as XY, XZ, XT, XYZ, XYT, and XYZT. Standard image formats, including TIFF and AVI, permit easy, direct export of FluoView images to off-line analysis packages. XY scanning is performed with a pair of galvanometric mirrors, yielding a wide scanning range to cover up to a field number of 20. The optical zoom (up to 10x magnification) can be performed by narrowing the scanning range while maintaining the maximum pixel resolution of up to 2048 x 2048 pixels.

View all literature mentions