High-resolution in vivo imaging of higher vertebrate embryos over short or long time periods under constant physiological conditions is a technically challenging task for researchers working on cardiovascular development. In chick embryos, for example, various studies have shown that without appropriate maintenance of temperature, as one of the main environmental factors, the embryonic heart rate drops rapidly and often results in an increase in regurgitant flow. Hemodynamic parameters are critical stimuli for cardiovascular development that, for a correct evaluation of their developmental significance, should be documented under physiological conditions. However, previous studies were mostly carried out outside of an incubator or under suboptimal environmental conditions. Here we present, to the best of our knowledge, the first detailed description of an optical coherence tomography (OCT) system integrated into an examination incubator to facilitate real-time in vivo imaging of cardiovascular development under physiological environmental conditions. We demonstrate the suitability of this OCT examination incubator unit for use in cardiovascular development studies by examples of proof of principle experiments. We, furthermore, point out the need for use of examination incubators for physiological OCT examinations by documenting the effects of room climate (22°C) on the performance of the cardiovascular system of chick embryos (HH-stages 16/17). Upon exposure to room climate, chick embryos showed a fast drop in the heart rate and striking changes in the cardiac contraction behaviour and the blood flow through the vitelline circulation. We have documented these changes for the first time by M-mode OCT and Doppler M-mode OCT.
Pubmed ID: 21641190
Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.
:OsiriX is an image processing software dedicated to DICOM images (.dcm / .DCM extension) produced by medical equipment (MRI, CT, PET, PET-CT, ...) and confocal microscopy (LSM and BioRAD-PIC format). It can also read many other file formats: TIFF (8,16, 32 bits), JPEG, PDF, AVI, MPEG and Quicktime. It is fully compliant with the DICOM standard for image comunication and image file formats. OsiriX is able to receive images transferred by DICOM communication protocol from any PACS or medical imaging modality (STORE SCP - Service Class Provider, STORE SCU - Service Class User, and Query/Retrieve) . OsiriX has been specifically designed for navigation and visualization of multimodality and multidimensional images: 2D Viewer, 3D Viewer, 4D Viewer (3D series with temporal dimension, for example: Cardiac-CT) and 5D Viewer (3D series with temporal and functional dimensions, for example: Cardiac-PET-CT). The 3D Viewer offers all modern rendering modes: Multiplanar reconstruction (MPR), Surface Rendering, Volume Rendering and Maximum Intensity Projection (MIP). All these modes support 4D data and are able to produce image fusion between two different series (for example: PET-CT). Osirix is at the same time a DICOM PACS workstation for medical imaging and an image processing software for medical research (radiology and nuclear imaging), functional imaging, 3D imaging, confocal microscopy and molecular imaging. :
View all literature mentions