The electrogenic Na+/HCO3- cotransport modulates resting membrane potential and action potential duration in cat ventricular myocytes.

María C Villa-Abrille | Martín G Vila Petroff | Ernesto A Aiello
The Journal of physiology | 2007

Perforated whole-cell configuration of patch clamp was used to determine the contribution of the electrogenic Na+/HCO3- cotransport (NBC) on the shape of the action potential in cat ventricular myocytes. Switching from Hepes to HCO3- buffer at constant extracellular pH (pH(o)) hyperpolarized resting membrane potential (RMP) by 2.67 +/- 0.42 mV (n = 9, P < 0.05). The duration of action potential measured at 50% of repolarization time (APD50) was 35.8 +/- 6.8% shorter in the presence of HCO3- than in its absence (n = 9, P < 0.05). The anion blocker SITS prevented and reversed the HCO3- -induced hyperpolarization and shortening of APD. In addition, no HCO3- -induced hyperpolarization and APD shortening was observed in the absence of extracellular Na+. Quasi-steady-state currents were evoked by 8 s duration voltage-clamped ramps ranging from -130 to +30 mV. A novel component of SITS-sensitive current was observed in the presence of HCO3-. The HCO3- -sensitive current reversed at -87 +/- 5 mV (n = 7), a value close to the expected reversal potential of an electrogenic Na+/HCO3- cotransport with a HCO3-:Na+ stoichiometry ratio of 2: 1. The above results allow us to conclude that the cardiac electrogenic Na+/HCO3- cotransport has a relevant influence on RMP and APD of cat ventricular cells.

Pubmed ID: 17138608

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


pClamp (tool)

RRID:SCR_011323

Software suite for electrophysiology data acquisition and analysis by Molecular Devices. Used for the control and recording of voltage clamp, current clamp, and patch clamp experiments. The software suite consists of Clampex 11 Software for data acquisition, AxoScope 11 Software for background recording, Clampfit 11 Software for data analysis, and optional Clampfit Advanced Analysis Module for sophisticated and streamlined analysis.