Influence of image analysis strategy, cooling rate, and sample volume on apparent protein cloud-point temperature determination.

Marieke E Klijn | Jürgen Hubbuch
Bioprocess and biosystems engineering | 2021

The protein cloud-point temperature (TCloud) is a known representative of protein-protein interaction strength and provides valuable information during the development and characterization of protein-based products, such as biopharmaceutics. A high-throughput low volume TCloud detection method was introduced in preceding work, where it was concluded that the extracted value is an apparent TCloud (TCloud,app). As an understanding of the apparent nature is imperative to facilitate inter-study data comparability, the current work was performed to systematically evaluate the influence of 3 image analysis strategies and 2 experimental parameters (sample volume and cooling rate) on TCloud,app detection of lysozyme. Different image analysis strategies showed that TCloud,app is detectable by means of total pixel intensity difference and the total number of white pixels, but the latter is also able to extract the ice nucleation temperature. Experimental parameter variation showed a TCloud,app depression for increasing cooling rates (0.1-0.5 °C/min), and larger sample volumes (5-24 μL). Exploratory thermographic data indicated this resulted from a temperature discrepancy between the measured temperature by the cryogenic device and the actual sample temperature. Literature validation confirmed that the discrepancy does not affect the relative inter-study comparability of the samples, regardless of the image analysis strategy or experimental parameters. Additionally, high measurement precision was demonstrated, as TCloud,app changes were detectable down to a sample volume of only 5 μL and for 0.1 °C/min cooling rate increments. This work explains the apparent nature of the TCloud detection method, showcases its detection precision, and broadens the applicability of the experimental setup.

Pubmed ID: 33237399

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


MATLAB (tool)

RRID:SCR_001622

Multi paradigm numerical computing environment and fourth generation programming language developed by MathWorks. Allows matrix manipulations, plotting of functions and data, implementation of algorithms, creation of user interfaces, and interfacing with programs written in other languages, including C, C++, Java, Fortran and Python. Used to explore and visualize ideas and collaborate across disciplines including signal and image processing, communications, control systems, and computational finance.