Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

ANI and BIS variations in supine and prone position during closed-tracheal suction in sedated and myorelaxed ICU patients with severe COVID-19: A retrospective study.

E Boselli | A Fatah | S Ledochowski | B Allaouchiche
Journal of clinical monitoring and computing | 2021

The purpose of this study was to assess Analgesia/Nociception Index (ANI) and bispectral index (BIS) variations in supine and prone position during closed-tracheal suction in intensive care unit (ICU) patients with severe COVID-19 pneumonia requiring myorelaxation and prone positioning. We retrospectively reviewed the data of 15 patients hospitalized in ICU for severe COVID-19 pneumonia requiring sedation, myorelaxation and prone positioning. The BIS, instant ANI (ANIi), mean ANI (ANIm), heart rate (HR), systolic blood pressure (SBP) and SpO2 were retrieved in supine and prone position 1 min before tracheal suction then every minute from the beginning of tracheal suction during 4 min and compared using ANOVA for repeated measures (p < 0.05 considered as statistically significant). Both ANIm and ANIi decreased significantly during tracheal suction with no difference between positions, whereas BIS showed no significant variation within time and between groups. The median [Q1-Q3] ANIm value decreased from 87 [68-98] to 79 [63-09] in supine position and from 79 [63-95] to 78 [66-98] in prone position 2 min after the beginning of tracheal suction. The median [Q1-Q3] ANIi value decreased earlier 1 min after the beginning of tracheal suction from 84 [69-98] to 73 [60-90] in supine position and from 84 [60-99] to 71 [51-88] in prone position. Both HR, SBP and SpO2 varied modestly but significantly during tracheal suction with no difference between positions. Monitoring ANI, but not BIS, may be of interest to detect noxious stimuli such as tracheal suction in ICU myorelaxed patients with severe COVID-19 pneumonia requiring prone positioning.

Pubmed ID: 33159268

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


MedCalc (tool)

RRID:SCR_015044

Statistical software for ROC curve analysis. MedCalc performs several statistical tests such as method comparison, method evaluation, reference intervals, and meta-analysis.

View all literature mentions