Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Stereolithographic Surgical Guide with a Combination of Tooth and Bone Support: Accuracy of Guided Implant Surgery in Distal Extension Situation.

Chia-Cheng Lin | Masahiro Ishikawa | Takeo Maida | Hsin-Chung Cheng | Keng-Liang Ou | Takashi Nezu | Kazuhiko Endo
Journal of clinical medicine | 2020

A distal free-end situation could result in insufficient stability of the surgical guide, and could reduce accuracy of the static guided implant surgery (sGIS). The purpose of this study was to investigate the accuracy of sGIS using a combination tooth-and-bone supported stereolithographic (SLA) surgical guide in distal extension situation. Thirty dentists, each placed three implants at the Federal Dentaire Internationale (FDI) teeth positions #46, #47 (a distal extension situation), and #36 (a single tooth gap) via the surgical guide on a model fixed to a manikin. Pre- and post-operative computed tomography (CT) images of the models were superimposed, and the positional and angular deviations of the implants were measured with metrology software. An analysis of variance (ANOVA) test was performed to evaluate the intergroup differences. No significant differences were found for all the positional and angular deviations among the three implant sites, except the bucco-lingual deviation at the implant platform in the #47 position (0.43 ± 0.19 mm) that was significantly larger than the #46 (0.21 ± 0.14 mm) and #36 (0.24 ± 0.25 mm) positions (p < 0.0001). Within the limits of this study, we conclude that, in distal extension situation of missing mandibular molars, adding a bone-supported strut in the distal part of the surgical guide can be beneficial to the accuracy of the sGIS.

Pubmed ID: 32151043

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Stata (tool)

RRID:SCR_012763

A Software resource for statistical analysis and presentation of graphics.

View all literature mentions