Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Estimation of three-dimensional long axes of the maxillary and mandibular first molars with regression analysis.

Kazuto Terada | Takashi Kameda | Ikuo Kageyama | Makoto Sakamoto
Anatomical science international | 2020

The purpose of this study was to determine the long axes of molars with multiple roots through ordinary least squares regression (LSR) and to compare them with the axes defined by principal component analysis (PCA). Three-dimensional radiological images of 20 dry skulls were obtained by cone-beam computed tomography (CBCT). Data from maxillary and mandibular first molars were extracted from the CBCT DICOM data with a three-dimensional image visualization system. The obtained data were reconstructed, converted to STL files, and three-dimensional coordinate values were extracted. The long axes were estimated by an algorithm to synchronize the LSR line with the horizontal axis which was translated to the vertical axis. The axes of the molars defined by LSR were compared with the axes of the molars defined by PCA. The coordinate point number of each molar was 5400-5800. The algorithm for determining the tooth axes in this study consisted of four stages containing three steps each. The distance between the two axes calculated by the two methods (LSR and PCA) on the horizontal plane through the origin was less than 10-12 mm and the deviations between them were less than 0.003°. The long axes of the molars estimated by LSR agree almost exactly with the axes estimated by PCA, and the accuracy is sufficient for clinical usage; however, the distance between them would shorten with a more severe convergence condition of the α value at each stage of this LSR system.

Pubmed ID: 31654329

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Microsoft Excel (tool)

RRID:SCR_016137

Software application with data analysis tools and spreadsheet templates to track and visualize data. It is used to manage and process data.

View all literature mentions