Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Deploying Clinical Process Improvement Strategies to Reduce Motion Artifacts and Expiratory Phase Scanning in Chest CT.

Ruhani Doda Khera | Ramandeep Singh | Fatemeh Homayounieh | Evan Stone | Travis Redel | Cristy A Savage | Katherine Stockton | Jo-Anne O Shepard | Mannudeep K Kalra | Subba R Digumarthy
Scientific reports | 2019

We hypothesized that clinical process improvement strategies can reduce frequency of motion artifacts and expiratory phase scanning in chest CT. We reviewed 826 chest CT to establish the baseline frequency. Per clinical process improvement guidelines, we brainstormed corrective measures and priority-pay-off matrix. The first intervention involved education of CT technologists, following which 795 chest CT were reviewed. For the second intervention, instructional videos on optimal breath-hold were shown to 245 adult patients just before their chest CT. Presence of motion artifacts and expiratory phase scanning was assessed. We also reviewed 311 chest CT scans belonging to a control group of patients who did not see the instructional videos. Pareto and percentage run charts were created for baseline and post-intervention data. Baseline incidence of motion artifacts and expiratory phase scanning in chest CT was 35% (292/826). There was no change in the corresponding incidence following the first intervention (36%; 283/795). Respiratory motion and expiratory phase chest CT with the second intervention decreased (8%, 20/245 patients). Instructional videos for patients (and not education and training of CT technologists) reduce the frequency of motion artifacts and expiratory phase scanning in chest CT.

Pubmed ID: 31413297

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Microsoft Excel (tool)

RRID:SCR_016137

Software application with data analysis tools and spreadsheet templates to track and visualize data. It is used to manage and process data.

View all literature mentions