Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
Here we describe baseline validation studies and field performance of a research-use-only chemiluminescent multiplex serology panel for measles, mumps, rubella, and varicella-zoster virus used with dried blood spots in support of the 2013-2014 Democratic Republic of the Congo Demographic and Health Survey. Characterization of the panel using U.S. FDA-cleared commercial kits shows good concordance for measles, mumps, rubella, and varicella-zoster with average sensitivity across assays of 94.9% and an average specificity of 91.4%. As expected, performance versus available standards validated for plaque-reduction assays does not provide a 1:1 correspondence with international units and yet demonstrates excellent linearity (average Hill's slope = 1.02) and ∼4 logs of dynamic range. In addition, for the four assays, the multiplexed format allowed for inclusion of three positive and two negative controls for each sample. A prototype Dynex Multiplier chemiluminescent automated immunoassay instrument with a charge-coupled device camera provided a rugged and robust processing and data acquisition platform. Performance of a multiplex instrument for serological testing in a substantially resource-limited environment shows excellent reproducibility, minimal cross-reactivity, and a clear discrimination between specific assays and should be considered a viable option for future serosurveys.IMPORTANCE The critical evaluation of immunization programs is key to identifying areas of suboptimal vaccination coverage, monitoring activities, and aiding development of public health policy. For evaluation of vaccine effectiveness, direct antibody binding assay methods, including enzyme immunoassay, enzyme-linked fluorescence assays, and indirect immunofluorescence assay, are most commonly used for detection of IgG antibodies. However, despite their well-demonstrated, reliable performance, they can be labor-intensive and time-consuming and require separate assays for each individual marker. This necessitates increased sample volumes, processing time, and personnel, which may limit assessment to a few key targets in resource-limited settings, that is, low- and middle-income locations where funding for public health or general infrastructure that directly impacts public health is restricted, limiting access to equipment, infrastructure, and trained personnel. One solution is a multiplexed immunoassay, which allows for the detection of multiple analytes in a single reaction for increased efficiency and rapid surveillance of infectious diseases in limited-resource settings. Thus, the scope of the project precluded a full validation, and here we present abbreviated validation studies demonstrating adequate sensitivity, specificity, and reproducibility.
Pubmed ID: 31413172
Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.
THIS RESOURCE IS NO LONGER IN SERVICE, documented on February 1st, 2022. Software application for genetic analysis of classical biometric traits like blood pressure or height that are caused by a combination of polygenic inheritance and complex environmental forces. (entry from Genetic Analysis Software)
View all literature mentionsSoftware for the efficient and robust de novo reconstruction of transcriptomes from RNA-seq data.
View all literature mentionsSoftware application with data analysis tools and spreadsheet templates to track and visualize data. It is used to manage and process data.
View all literature mentionsCell line MRC-5 is a Finite cell line with a species of origin Homo sapiens
View all literature mentions