Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Appropriateness of Prescription and Safety of Wearable Cardioverter Defibrillators: A Single-center Experience.

Murtaza Sundhu | Sajjad Gul | Mubbasher A Syed | Omer Afzal | Bhavan Shah | Lon Castle
Cureus | 2019

Introduction Wearable cardioverter defibrillators (WCD) are recommended for patients with a high risk of sudden cardiac death (SCD) secondary to arrhythmia that have not qualified for placement of an implantable cardiac defibrillator (ICD). This study provides insights into a single-center experience with WCD in terms of its usage and safety. Materials and methods We studied all patients that were prescribed a WCD in the Fairview Hospital in Cleveland Clinic Health System, from January 2014 to June 2016. Institutional Review Board of the Cleveland Clinic approved the study. A retrospective chart review was performed to collect data regarding demographics and baseline comorbidities including age, gender, history of hypertension, diabetes, coronary artery disease, and chronic kidney disease. The patients that were lost to follow up in our electronic medical record (EMR) were excluded. Ejection fraction (EF) at the time of diagnosis and follow-up was recorded. The primary outcome was ICD placement at follow up focusing on appropriate use while the secondary outcome was delivery of shock (appropriate or inappropriate) focusing on efficacy and safety of the device. Patients were stratified based on ICD placement. Statistical Package for the Social Sciences (SPSS), version 23 (IBM Corp., NY, USA) was used for the statistical analysis. Results We identified 73 patients with WCD placement. After the exclusion of 23/73 (31.5%) patients due to loss of follow-up, 50 patients were included in the study (n=50). Clinical characteristics showed 66% patients were males, 76% had hypertension, 40% had diabetes, 34% had chronic kidney disease, 56% patient had a New York Heart Association functional status of >II and 34% were on anti-arrhythmic medication. Indication for WCD use was ischemic cardiomyopathy in 23/50 (46%) patients and non-ischemic cardiomyopathy in 27/50 (54%) patients. No ICD was placed in 39/50 (78%) patients and ICD was placed in 11/50 (22%) patients at end time of follow up. Mean age was 59.9 years (95% confidence interval (CI), 55.9 - 63.9 years) in the group with no ICD placement and 63.5 years (95% CI, 56.5 - 70.6 years) in the group with ICD placement. Mean EF in the group with no ICD placement at the time of diagnosis was 25.8% (95% CI, 23.8% - 27.9%) which improved by 18.8% to a mean EF of 44.6% (41.1% - 48.1%) at the follow-up. Mean EF in the group with ICD placement was 32.7% (95% CI, 27.6% - 37.9%) which reduced by 4.1% to mean EF of 28.6% (95% CI, 12.2% - 44.9%) which was statistically significant (p<0.0001). Patients who had no ICD placement were followed for an average of 162 days and with ICD placement for 78 days. There was no difference between ischemic or nonischemic groups in getting the ICD. There were no shocks delivered whether appropriate or inappropriate in our population. Conclusion Almost a quarter of the patients that were prescribed WCD in our center ended up with an implanted device which demonstrates appropriate use. Equally important was the observed safety of WCDs as a treatment modality with no inappropriate shocks recorded in the followed cohort.

Pubmed ID: 31410337

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Microsoft Excel (tool)

RRID:SCR_016137

Software application with data analysis tools and spreadsheet templates to track and visualize data. It is used to manage and process data.

View all literature mentions