Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Enzymatic Reactions in a Lab-on-Valve System: Cholesterol Evaluations.

Jucineide S Barbosa | Marieta L C Passos | M das Graças A Korn | M Lúcia M F S Saraiva
Molecules (Basel, Switzerland) | 2019

The micro sequential injection analysis / lab-on-valve (µSIA-LOV) system is a miniaturized SIA system resulting from the implementation of a lab-on-valve (LOV) atop of the selection valve. It integrates the detection cell and the sample processing channels into the same device, promoting the reduction of reagent consumption and waste generation, the improvement of the versatility, and the reduction of the time of analysis. All of these characteristics are really relevant to the implementation of enzymatic reactions. Additionally, the evaluation of cholesterol in serum samples is widely relevant in clinical diagnosis, since higher values of cholesterol in human blood are actually an important risk factor for cardiovascular problems. An automatic methodology was developed based on the µSIA-LOV system in order to evaluate its advantages in the implementation of enzymatic reactions performed by cholesterol esterase, cholesterol oxidase and peroxidase. Considering these reactions, the developed methodology was also used for the evaluation of cholesterol in human serum samples, showing reliable and accurate results. The developed methodology presented detection and quantification limits of 1.36 and 4.53 mg dL-1 and a linear range up to 40 mg dL-1. This work confirmed that this µSIA-LOV system is a simple, rapid, versatile, and robust analytical tool for the automatic implementation of enzymatic reactions performed by cholesterol esterase, cholesterol oxidase, and peroxidase. It is also a useful alternative methodology for the routine determinations of cholesterol in real samples, even when compared with other automatic methodologies.

Pubmed ID: 31395798

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Millipore (tool)

RRID:SCR_008983

An Antibody supplier

View all literature mentions