Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Determination of Metals in Natural Waters by Inductively Coupled Plasma Optical Emission Spectroscopy after Preconcentration on Silica Sequentially Coated with Layers of Polyhexamethylene Guanidinium and Sulphonated Nitrosonaphthols.

Svetlana L Didukh-Shadrina | Vladimir N Losev | Alexandr Samoilo | Anatoliy К Trofimchuk | Pavel N Nesterenko
International journal of analytical chemistry | 2019

A series of complexing adsorbents is prepared by coating silica particles with linear polyhexamethylene guanidinium (PHMG) chloride followed by saturation with a number of sulphonated nitrosonaphthols reagents electrostatically retained by positively charged polymer layer. PHMG coated silica is hydrolytically stable even during treatment with 6 M HCl heated up to 50 °C. The adsorption of 1-nitroso-2-naphthol-3,6-disulfonic acid (nitroso-R-salt), 2-nitroso-1-naphthol-4-sulfonic acid (nitroso-N-salt), and 2-nitroso-1-naphthol-3,6-disulfonic acid (nitroso-K-salt) on PHMG modified silica was studied. The effective immobilisation of sulphonated nitrosonaphthols was achieved in the range of pH of 3 - 8, while the adsorption of the monosulphonated reagent (nitroso-N-salt) is twice as high as the disulphonated analogues (nitroso-R-salt and nitroso-K-salt). The adsorption of Cu(II), Fe(III), Co(II), Ni(II), Al(III), Zn(II), Pb(II), Mn(II), and Cr(III) on prepared complexing adsorbents under static and dynamic conditions was studied as a function of time, pH, sample volume, and presence of interfering ions. Metal ions can be desorbed by using 1 M HCl or 1 M HNO3. The preconcentration factors of metals under optimized conditions are varied from 20 to 80. The developed method was used for the preconcentration of trace metals from natural waters followed by ICP-OES determination. The sub-ppb limits of detection of metals are achieved.

Pubmed ID: 31354824

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Thermo Fisher Scientific (tool)

RRID:SCR_008452

Commercial vendor and service provider of laboratory reagents and antibodies. Supplier of scientific instrumentation, reagents and consumables, and software services.

View all literature mentions

Sigma-Aldrich (tool)

RRID:SCR_008988

American chemical, life science and biotechnology company owned by Merck KGaA. Merger of Sigma Chemical Company and Aldrich Chemical Company. Provides organic and inorganic chemicals, building blocks, reagents, advanced materials and stable isotopes for chemical synthesis, medicinal chemistry and materials science, antibiotics, buffers, carbohydrates, enzymes, forensic tools, hematology and histology, nucleotides, proteins, peptides, amino acids and their derivatives.

View all literature mentions