Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

A valve powered by earthworm muscle with both electrical and 100% chemical control.

Yo Tanaka | Shun-Ichi Funano | Yuji Noguchi | Yaxiaer Yalikun | Norihiro Kamamichi
Scientific reports | 2019

Development of bio-microactuators combining microdevices and cellular mechanical functions has been an active research field owing to their desirable properties including high mechanical integrity and biocompatibility. Although various types of devices were reported, the use of as-is natural muscle tissue should be more effective. An earthworm muscle-driven valve has been created. Long-time (more than 2 min) and repeatable displacement was observed by chemical (acetylcholine) stimulation. The generated force of the muscle (1 cm × 3 cm) was 1.57 mN on average for 2 min by the acetylcholine solution (100 mM) stimulation. We demonstrated an on-chip valve that stopped the constant pressure flow by the muscle contraction. For electrical control, short pulse stimulation was used for the continuous and repeatable muscle contraction. The response time was 3 s, and the pressure resistance was 3.0 kPa. Chemical stimulation was then used for continuous muscle contraction. The response time was 42 s, and the pressure resistance was 1.5 kPa. The ON (closed) state was kept for at least 2 min. An on-chip valve was demonstrated that stopped the constant pressure flow by the muscle contraction. This is the first demonstration of the muscle-based valve that is 100% chemically actuated and controlled.

Pubmed ID: 31285453

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Thermo Fisher Scientific (tool)

RRID:SCR_008452

Commercial vendor and service provider of laboratory reagents and antibodies. Supplier of scientific instrumentation, reagents and consumables, and software services.

View all literature mentions

Olympus cellSens Software (tool)

RRID:SCR_014551

Software suite for image acquisition and analysis. The software can be paired with high-quality cameras to maximize output quality and export it for sharing and research applications.

View all literature mentions