Left ventricular outflow obstruction predicts increase in systolic pressure gradients and blood residence time after transcatheter mitral valve replacement.

Adelaide De Vecchi | David Marlevi | David A Nordsletten | Ioannis Ntalas | Jonathon Leipsic | Vinayak Bapat | Ronak Rajani | Steven A Niederer
Scientific reports | 2018

Left ventricular outflow tract (LVOT) obstruction is a relatively common consequence of transcatheter mitral valve replacement (TMVR). Although LVOT obstruction is associated with heart failure and adverse remodelling, its effects upon left ventricular hemodynamics remain poorly characterised. This study uses validated computational models to identify the LVOT obstruction degree that causes significant changes in ventricular hemodynamics after TMVR. Seven TMVR patients underwent personalised flow simulations based on pre-procedural imaging data. Different virtual valve configurations were simulated in each case, for a total of 32 simulations, and the resulting obstruction degree was correlated with pressure gradients and flow residence times. These simulations identified a threshold LVOT obstruction degree of 35%, beyond which significant deterioration of systolic function was observed. The mean increase from baseline (pre-TMVR) in the peak systolic pressure gradient rose from 5.7% to 30.1% above this threshold value. The average blood volume staying inside the ventricle for more than two cycles also increased from 4.4% to 57.5% for obstruction degrees above 35%, while the flow entering and leaving the ventricle within one cycle decreased by 13.9%. These results demonstrate the unique ability of modelling to predict the hemodynamic consequences of TMVR and to assist in the clinical decision-making process.

Pubmed ID: 30341365

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

  • Agency: Wellcome Trust, United Kingdom
  • Agency: King's College London Medical Engineering Centre (Wellcome Trust EPSRC Centre of Excellence in Medical Engineering), International
    Id: WT 203148/Z/16/Z
  • Agency: Engineering and Physical Sciences Research Council (EPSRC), International
    Id: EP/M012492/1

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Medtronic (tool)

RRID:SCR_003988

Medical technology company that develops and manufactures devices and therapies to treat more than 30 chronic diseases, including heart failure, Parkinson's disease, urinary incontinence, Down syndrome, obesity, chronic pain, spinal disorders, and diabetes. A Commercial healthcare organization for both patients and healthcare professionals. For professionals, it provides products, therapy and procedure solutions, and services.