Background: The purpose of this study was to examine the convergent validity of the Polar Active Watch (PAW), a consumer-grade wrist-worn activity monitor, against waist- and wrist-worn research-grade monitors, the ActiGraph GT3X+/GT9X accelerometers, in children. Methods: Fifty-one children (18 boys; mean age = 10.30 ± 0.91 years) wore the three monitors (PAW, GT3X+, and GT9X) during an 80-min afterschool program across five school days. Time spent in sedentary, light-intensity (LPA), and moderate- and vigorous-intensity physical activity (MVPA) were estimated from each monitor. The correlation, mixed model, mean absolute percentage error, equivalence testing, and Bland-Altman analyses were used to examine the comparability of PA estimates of the PAW with GT3X+/GT9X accelerometers. Results: Moderate to strong correlations for sedentary and MVPA minutes, and weak correlation for LPA were observed between the PAW and GT3X+/GT9X accelerometers. Significant mean differences were found, where the PAW tended to overestimate time in sedentary and MVPA and underestimate LPA minutes, compared to the GT3X+/GT9X accelerometers. However, a non-significant mean difference in MVPA minutes was observed when using an adjusted MET threshold (≥4 METs) for the PAW, compared to the GT3X+ accelerometer. Conclusions: The PAW showed moderate convergent validity for sedentary and MVPA minutes against the GT3X+/GT9X accelerometers. However, caution is needed in the direct comparison between the monitors due to relatively large mean differences and within-group variability.
Pubmed ID: 30332785
Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.
Commercial instrument supplier for human activity monitors. ActiGraph devices are used by researchers and clinicians in hundreds of universities and research organizations in more than 56 countries. ActiGraph activity monitors are the most validated and widely used devices of their kind. ActiGraph activity monitors use triaxial accelerometers and our validated proprietary filtering algorithms to accurately measure the amount and intensity of human activity. They are powered by rechargeable lithium ion batteries, and battery charging and communication are accomplished via a standard USB connection. All ActiGraph activity monitors can be worn at the waist or wrist and are suitable for subjects of all ages. ActiGraph devices have been used in hundreds of research studies in nearly 60 countries around the world since 1992. Leading research facilities including the U.S. National Institute of Health (NIH), the Institute of Child Health in the UK, and Karolinska Institutet in Sweden rely on our products to provide objective activity measurement in dozens of areas including obesity, diabetes, sleep, elderly behavior, and athletics. ActiGraph often works with scientific organizations to develop and implement software and hardware features that reflect the evolving needs of the research community. ActiGraph devices are well recognized as some of the most accurate activity measurement products on the market. Extensive research has confirmed our accuracy against the VO2 and doubly labeled water (DLW) methods of estimating energy expenditure. Keywords: Device, Researcher, Clinician, University, Research, Organization, Obesity, Diabetes, Sleep, Elderly, Behavior, Athletics, Scientific, Activity monitor, Physical, Measurement, Human, Activity,
View all literature mentions