The Comparative Associations of Ultrasound and Computed Tomography Estimates of Muscle Quality with Physical Performance and Metabolic Parameters in Older Men.

Michael O Harris-Love | Nilo A Avila | Bernadette Adams | June Zhou | Bryant Seamon | Catheeja Ismail | Syed H Zaidi | Courtney A Kassner | Frank Liu | Marc R Blackman
Journal of clinical medicine | 2018

Estimates of muscle tissue composition may have greater prognostic value than lean body mass levels regarding health-related outcomes. Ultrasound provides a relatively low cost, safe, and accessible mode of imaging to assess muscle morphology. The purpose of this study was to determine the construct validity of muscle echogenicity as a surrogate measure of muscle quality in a sample of older, predominantly African American (AA) participants. We examined the association of rectus femoris echogenicity with mid-thigh computed tomography (CT) scan estimates of intra- and intermuscular adipose tissue (IMAT), basic metabolic parameters via blood sample analysis, muscle strength, and mobility status. This observational study was conducted at a federal medical center and included 30 community-dwelling men (age, 62.5 ± 9.2; AA, n = 24; Caucasian, n = 6). IMAT estimates were significantly associated with echogenicity (r = 0.73, p < 0.001). Echogenicity and IMAT exhibited similar associations with the two-hour postprandial glucose values and high-density lipoproteins values (p < 0.04), as well as grip and isokinetic (180°/s) knee extension strength adjusted for body size (p < 0.03). The significant relationship between ultrasound and CT muscle composition estimates, and their comparative association with key health-related outcomes, suggests that echogenicity should be further considered as a surrogate measure of muscle quality.

Pubmed ID: 30308959

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

  • Agency: RRD VA, United States
    Id: IK2 RX001854
  • Agency: NCATS NIH HHS, United States
    Id: UL1 TR001409
  • Agency: NCATS NIH HHS, United States
    Id: UL1 TR000101