Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

The effect of blood sampling and preanalytical processing on human N-glycome.

Tereza Dědová | Detlef Grunow | Kai Kappert | Dagmar Flach | Rudolf Tauber | Véronique Blanchard
PloS one | 2018

Glycome modulations have been described in the onset and progression of many diseases. Thus, many studies have proposed glycans from blood glycoproteins as disease markers. Astonishingly, little effort has been given unraveling preanalytical conditions potentially influencing glycan analysis prior to blood biomarker studies. In this work, we evaluate for the first time the effect of hemolysis, storage and blood collection, but also influence of various times and temperatures between individual processing steps on the total N-glycome and on a glycan-biomarker score. Venous blood was collected from 10 healthy donors in 11 blood collection tubes with different additives, processed variously to obtain 16 preanalytical variables and N-glycans released from serum or plasma were analyzed by MALDI-TOF-MS and capillary electrophoresis coupled with fluorescence detection (CE-LIF) for the first time. Long time storage of deep frozen samples at -20°C or -80°C exerted only a minor influence on the glycome as demonstrated by CE-LIF. The N-glycome was very stable evidenced by MALDI-TOF when stored at 4°C for at least 48 hours and blood collected in tubes devoid of additives. The glycome was stable upon storage after centrifugation and aliquoting, which is an important information considering future diagnostic applications. Hemolysis, however, negatively correlated with an established glycan score for ovarian cancer, when evaluated by MALDI-TOF-MS measurement by affecting relative intensities of certain glycans, which could lead to false negative / positive results in glycan biomarker studies.

Pubmed ID: 29995966

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Millipore (tool)

RRID:SCR_008983

An Antibody supplier

View all literature mentions

NCBI accession download script (tool)

RRID:SCR_024130

Software tool as partner script to the popular ncbi-genome-download script. Allows to download sequences from GenBank/RefSeq by accession through the NCBI ENTREZ API.

View all literature mentions