Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
Brain metastases show a recurrence rate of about 50% after surgical resection. Adjuvant radiotherapy can prevent progression; however, whole-brain radiotherapy (WBRT) can be associated with significant side effects. Local hypofractionated stereotactic radiotherapy (HFSRT) is a good alternative to provide local control with minimal toxicity. In this multicenter analysis, we evaluated the treatment outcome of local HFSRT after resection brain metastases in 181 patients. Patient's characteristics, treatment data as well as follow-up data were collected and analyzed with special focus on local control, locoregional control and survival. After a median follow-up of 12.6 months (range 0.3-80.2 months), the crude rate for local control was 80.5%; 1- and 2-year local recurrence-free survival rates were 75% and 70% (median not reached). Resection cavity size was a significant predictor for local recurrence (P = 0.033). The median overall survival was 16.0 months. Both graded prognostic assessment score and recursive partitioning analysis were accurate predictors of survival. HFSRT leads to excellent local control and has a high potential to consolidate results after surgery; acute and late toxicity is low. Distant intracerebral metastases occur frequently during follow-up, and therefore, a close patient monitoring needs to be warranted if whole-brain radiotherapy is omitted.
Pubmed ID: 29696815
Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.
An application to visualize, segment, and quantify three-dimensional images. Multiple datasets may be loaded, displayed, fused, processed, and quantitatively analyzed simultaneously. Data may be imported from any DICOM-compatible three dimensional imaging modality. Regions-of-interest may be defined using a number of manual, semi-automatic, and automated tools to segment three-dimensional pixel volumes. They may also be imported from and exported to DICOM structure sets. This software has been applied to preclinical and clinical computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), and optical imaging data.
View all literature mentions