Collagen Type I Conduits for the Regeneration of Nerve Defects.

Silvan Klein | Jody Vykoukal | Oliver Felthaus | Thomas Dienstknecht | Lukas Prantl
Materials (Basel, Switzerland) | 2016

To date, reliable data to support the general use of biodegradable materials for bridging nerve defects are still scarce. We present the outcome of nerve regeneration following type I collagen conduit nerve repair in patients with large-diameter nerve gaps. Ten patients underwent nerve repair using a type I collagen nerve conduit. Patients were re-examined at a minimal follow-up of 14.0 months and a mean follow-up of 19.9 months. Regeneration of nerve tissue within the conduits was assessed by nerve conduction velocity (NCV), a static two-point discrimination (S2PD) test, and as disability of arm shoulder and hand (DASH) outcome measure scoring. Quality of life measures including patients' perceived satisfaction and residual pain were evaluated using a visual analog scale (VAS). No implant-related complications were observed. Seven out of 10 patients reported being free of pain, and the mean VAS was 1.1. The mean DASH score was 17.0. The S2PD was below 6 mm in 40%, between 6 and 10 mm in another 40% and above 10 mm in 20% of the patients. Eight out of 10 patients were satisfied with the procedure and would undergo surgery again. Early treatment correlated with lower DASH score levels. The use of type I collagen in large-diameter gaps in young patients and early treatment presented superior functional outcomes.

Pubmed ID: 28773346

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Integra Life Sciences (tool)

RRID:SCR_010741

Commercial tissue bank for human tissues.

View all literature mentions