Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

3-dimensional examination of the adult mouse subventricular zone reveals lineage-specific microdomains.

Kasum Azim | Roberto Fiorelli | Stefan Zweifel | Anahi Hurtado-Chong | Kazuaki Yoshikawa | Lutz Slomianka | Olivier Raineteau
PloS one | 2012

Recent studies suggest that the subventricular zone (SVZ) of the lateral ventricle is populated by heterogeneous populations of stem and progenitor cells that, depending on their exact location, are biased to acquire specific neuronal fates. This newly described heterogeneity of SVZ stem and progenitor cells underlines the necessity to develop methods for the accurate quantification of SVZ stem and progenitor subpopulations. In this study, we provide 3-dimensional topographical maps of slow cycling "stem" cells and progenitors based on their unique cell cycle properties. These maps revealed that both cell populations are present throughout the lateral ventricle wall as well as in discrete regions of the dorsal wall. Immunodetection of transcription factors expressed in defined progenitor populations further reveals that divergent lineages have clear regional enrichments in the rostro-caudal as well as in the dorso-ventral span of the lateral ventricle. Thus, progenitors expressing Tbr2 and Dlx2 were confined to dorsal and dorso-lateral regions of the lateral ventricle, respectively, while Mash1+ progenitors were more homogeneously distributed. All cell populations were enriched in the rostral-most region of the lateral ventricle. This diversity and uneven distribution greatly impede the accurate quantification of SVZ progenitor populations. This is illustrated by measuring the coefficient of error of estimates obtained by using increasing section sampling interval. Based on our empirical data, we provide such estimates for all progenitor populations investigated in this study. These can be used in future studies as guidelines to judge if the precision obtained with a sampling scheme is sufficient to detect statistically significant differences between experimental groups if a biological effect is present. Altogether, our study underlines the need to consider the SVZ of the lateral ventricle as a complex 3D structure and define methods to accurately assess neural stem cells or progenitor diversity and population sizes in physiological or experimental paradigms.

Pubmed ID: 23166605

Research resources used in this publication

None found

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Imaris (tool)

RRID:SCR_007370

Imaris provides range of capabilities for working with three dimensional images. Uses flexible editing and processing functions, such as interactive surface rendering and object slicing capabilities. And output to standard TIFF, Quicktime and AVI formats. Imaris accepts virtually all image formats that are used in confocal microscopy and many of those used in wide-field image acquisition.

View all literature mentions

Olympus FluoView 300 Confocal Microscope (tool)

RRID:SCR_020345

Confocal microscopy can improve conventional fluorescence images by recording fluorescence generated from the focal plane within the sample, while rejecting all other light coming from above or below the focal plane. The efficient point-scan/pinhole-detection confocal optics of the FluoView systems virtually eliminate out of focus light to produce high-contrast images with superb resolution. The FluoView systems are fully integrated workstations that incorporate user-friendly image acquisition and image analysis software with high-resolution confocal optics that require no user alignment. An , Windows-based graphic user interface allows new users to quickly generate images in various scan modes, such as XY, XZ, XT, XYZ, XYT, and XYZT. Standard image formats, including TIFF and AVI, permit easy, direct export of FluoView images to off-line analysis packages. XY scanning is performed with a pair of galvanometric mirrors, yielding a wide scanning range to cover up to a field number of 20. The optical zoom (up to 10x magnification) can be performed by narrowing the scanning range while maintaining the maximum pixel resolution of up to 2048 x 2048 pixels.

View all literature mentions

Olympus FluoView 300 Confocal Microscope (tool)

RRID:SCR_020339

Confocal microscopy can improve conventional fluorescence images by recording fluorescence generated from the focal plane within the sample, while rejecting all other light coming from above or below the focal plane. The efficient point-scan/pinhole-detection confocal optics of the FluoView systems virtually eliminate out of focus light to produce high-contrast images with superb resolution. The FluoView systems are fully integrated workstations that incorporate user-friendly image acquisition and image analysis software with high-resolution confocal optics that require no user alignment. An , Windows-based graphic user interface allows new users to quickly generate images in various scan modes, such as XY, XZ, XT, XYZ, XYT, and XYZT. Standard image formats, including TIFF and AVI, permit easy, direct export of FluoView images to off-line analysis packages. XY scanning is performed with a pair of galvanometric mirrors, yielding a wide scanning range to cover up to a field number of 20. The optical zoom (up to 10x magnification) can be performed by narrowing the scanning range while maintaining the maximum pixel resolution of up to 2048 x 2048 pixels.

View all literature mentions

C57BL/6J (tool)

RRID:IMSR_JAX:000664

Mus musculus with name C57BL/6J from IMSR.

View all literature mentions

B6;FVB-Tg(Dlx2-EGFP)HS66Gsat/Mmucd (tool)

RRID:MMRRC_016861-UCD

Mus musculus with name B6;FVB-Tg(Dlx2-EGFP)HS66Gsat/Mmucd from MMRRC.

View all literature mentions