Searching the Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes

Left ventricular longitudinal function assessed by speckle tracking ultrasound from a single apical imaging plane.

Thomas Bagger | Erik Sloth | Carl-Johan Jakobsen
Critical care research and practice | 2012

Background. Transthoracic ultrasonography of the heart is valuable in monitoring and treatment of critically ill patients. Speckle tracking ultrasound (STU) has proven valid in estimating left ventricular systolic deformation. The aims of the study were to compare conventional and automated STU and to determine whether left ventricular systolic deformation could be estimated from one single imaging plane. Methods. 2D-echocardiography cine-loops were obtained from 20 patients for off-line speckle tracking analysis, consisting of manually tracing of the endocardial border (conventional method) or automatically drawn boundaries (automated method). Results. We found a bias of 0,6 (95% CI -2.2-3.3) for global peak systolic strain comparing the automated and the conventional method. Comparing global peak systolic strain of apical 4-chamber cine-loops with averaged Global Peak Strain obtained from apical 4, 2 and long axis cine-loops, showed a bias of 0.1 (95% CI -3.9-4.0). The agreement between subcostal 4-chamber and apical 4-chamber global peak systolic strain was 4.4 (95% CI -3.7-12.5). Conclusion. We found good agreement between the conventional and the automated method. STU applied to single apical 4-chamber cine-loops is in excellent agreement with overall averaged global peak systolic strain, while subcostal 4-chamber cine-loops proved less compliant with speckle tracking ultrasound.

Pubmed ID: 22611488

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


MedCalc (tool)

RRID:SCR_015044

Statistical software for ROC curve analysis. MedCalc performs several statistical tests such as method comparison, method evaluation, reference intervals, and meta-analysis.

View all literature mentions