PCR Setup Robot. Compact benchtop instrument for setup of PCR experiments with setup and automatic calculation of all mixes, eliminating the need to program pipetting steps.
In vivo imaging system that combines two dimensional and three dimensional optical tomography in one platform.The system uses leading optical technology for preclinical imaging research and development best for non-invasive longitudinal monitoring of disease progression, cell trafficking and gene expression patterns in living animals.
Sequencer that uses pyrosequencing technology for real time, sequence based detection, quantification of sequence variants, and epigenetic methylation. Used for analysis of CpG methylation, SNPs, insertion deletions, STRs, variable gene copy number, and for microbial identification and resistance typing.
ProteOn XPR36 protein interaction array system is surface plasmon resonance (SPR) biosensor platform that provides real-time label-free analysis of specificity, affinity and kinetics of biomolecular interactions.
Purification system that performs fully automated purification of nucleic acids and proteins in molecular biology applications.
Sequencing and quantification platform for epigenetics, mutation gene expression analysis, and microbial identification and resistance typing. With its 96-well format, automatic base-calling function, and dedicated software solutions for methylation analysis and assay design.
Benchtop liquid handler designed to automate construction of 48 to 96 next generation sequencing libraries per day.
Dual channel fluorimeter for fluorescence measurements when calibrated with known concentration to measure compounds at low concentration with low assay volume.
Microplate luminometer that features two optional injectors and reads both glow- and flash-luminescent reactions in 96-well plates. The sensitivity and range enable a wide range of luminescent assays, including Promega bioluminescent reporter, cell-based and biochemical assays., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Luminometer combines instrumentation and software for uses includinh bioluminescent assays, protocols and support. You can measure flash or glow-type luminescence, have two fluorescent modules available, and it accommodates 1.5ml microcentrifuge tubes and 35mm petri dishes, with optional 12mm × 50mm test tube adapter. Measure light output from liquid and solid samples; no minimum volume requirements. The GloMax 20/20 blends user-friendly operation and a small footprint.This Instrument Was Retired September 1, 2023. Accessories and service available until September 1, 2028.
Microscope employs single zoom optical path with large diameter, which is optimized to collect light with efficiency and resolution at all magnifications. From fluorescent observation of whole organisms, such as zebrafish, at low magnification to detailed observation of gene expression at cellular level at high magnification, features pupil division mechanism in light path to mimic effect of stereo microscope.
Microwave sample preparation device system designed to count and size particles individually. It can used for in service oil samples with only 4 mL of 10 times diluted samples.
Benchtop liquid scintillation analyzer that detects small amounts of alpha, beta, and gamma radioactivity. Time resolved liquid scintillation counting is used for low background counting of LS samples., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Gamma counter available in single, five, or ten detector configurations. Can count RIA tubes, 16x100mm and variety of smaller micro tubes using available adapter.This instrument has dot Matrix Printer, tube racks, and protocol ID tags.Single detector model is available in 2 inch or 3 inch crystal configurations for research grade capabilities.
Laboratory microwave system that includes True Variable Wattage, water recirculation system, temperature restrictive temperature probe, RS232 Port, Cable and Software, Programmable times, Four intermittent power settings, Magnetron prewarming, Air Bubbler, and Vacuum Cycling. System has precision temperature control and monitoring for microwave assisted processing of tissue. Can be used for formalin fixation, decalcification, special stains, immunocytochemistry and complete processing of tissue into paraffin.
Intravital laser scanning microscope for small animal imaging with up to four lasers 488nm, 561nm, 633nm, and 748nm. Able to image multiple fluorescence probes simultaneously. Scan head has tilting capability to image objective orientation in three dimensions.Three magnifications of MicroProbe lenses enable to capture either large field of view or high resolution images on living animal. Certain conventional microscope objectives can also be used on IV100 as well.
Microscope equipped with CFI60 infinity optical system, providing images in all applications. Incorporates specifications adopted for CFI60 series objectives, including 60 millimeter parfocal distance, 25 millimeter thread size, and standard 22 millimeter field of view. Main components of CFI60 infinity optical system include objective, tube lens to converge light beam, and eyepiece lens to enlarge intermediate image. Fluorescence microscope that has detachable substage, 12 volt 100 watt tungsten halide lamp, filter magazine, and choice of sextuple nosepiece or sextuple DIC nosepiece.Has objectives for brightfield, darkfield, Nomarski DIC, epi fluorescence, or phase contrast techniques.
SMZ1500 stereoscopic zoom microscope is system with apochromatic objectives, zoom ratio of 15 to 1, range of magnifications from 0.75x to 11.25x for total magnifying capability of 3.75x up to 540x, and is best for in depth imaging.Zoom knob allows to zoom from 1x to 11x at 1x-intervals without interrupting observations. Other facets include high eyepoint eyepieces with built-in diopter adjustments, wide field of view, and built-in aperture diaphragm for achieving optimal depth of focus and improved photomicrography.Provides options of either low eye-level viewing tube or tilting eyepiece tube, with or without eye-level risers. Three different diascopic stands with built-in power supplies may also be utilized with instrument, or standard stand that features low profile for increased clearance.
Inverted fluorescence tissue culture microscope capable of imaging specimens in brightfield, darkfield, phase contrast, Hoffman modulation contrast, fluorescence, and differential interference contrast modes.TIRFM-IX illuminator is this microscope accessory which attaches to the rear lamphouse port and contains FC connector for external laser source and port for mercury or xenon lamp housing.
Nikon Instruments AZ100 C1si is macro confocal microscope system combining stereo and compound microscopes into single hybrid imaging system for dynamic imaging of single cells or whole specimens.System covers range of magnifications from 5x to 400x. Has triple nosepiece that can switch magnifications. AZ100 C1si boasts simultaneous 32 channel spectral image acquisition over spectral range of 320 nm in single scan. Simultaneous 32 channel acquisition at 10 nm, 5 nm or 2.5 nm bandwidths, all software controlled, is possible.