We support boolean queries, use +,-,<,>,~,* to alter the weighting of terms
Mass spectrometer that is used for analysis of large biomolecules (such as proteins, polymers, sugar, etc.) to identify and characterize the structures. The instrument has a capability of TOF/TOF technology (LIFT) for tandem MS (MS/MS). It is worked either linear or reflectron configuration with both positive and negative modes. System includes computer pre-loaded with software.
PCR assay kit that detects the five most prevalent carbapenemase gene families. Detection of carbapenemase genes from rectal swabs supports timely deployment of infection control procedures and appropriate patient management.
Goniometer that is used for macro molecular studies and submicron particle sizing with static and dynamic light scattering. It can be used with neutral density filters, polarizer, analyzer, and reference detector.
Optical thermal cycler that is capable of cycling and imaging up to three OpenArray plates simultaneously. System includes: NT Cycler, computer, flat-panel monitor, OpenArray AutoLoader, and Case Sealing Station. Requires analysis software kit for operation.
BMG LABTECH's SPECTROstar NANO is the premiere absorbance microplate reader. The SPECTROstar NANO is a spectrometer-based absorbance reader that can capture a full UV-visible spectrum, 220nm to 1000nm, in less than 1 sec/well at 1nm resolution, offering you speed and precision that cannot be matched by older monochromator or filter absorbance reading technology. The SPECTROstar NANO has a built in cuvette port, 45C incubation, push button operation, is 1536 well capable, and has 2uL nano spot DNA quantitation capability allow the fastest measurements of DNA, RNA, ELISAs, and much more.
Synergy H4 combines the sensitivity of a filter-based system with the of monochromator-based optics to provide the broadest range of applications available on the market today. Detection modes: Fluorescence Intensity, Time-Resolved Fluorescence, Fluorescence Polarization, AlphaScreen/AlphaLISA, Luminescence, UV-Visible absorbance, FRET, TR-FRET, BRET, well area scanning and spectral scanning.Synergy H4 optics incorporates two double-grating monochromators. This quadruple design provides the best in spectral scanning performance and flexibility. Synergy H4's filter/dichroic combination provides the best possible performance in fluorescence, time resolved fluorescence and fluorescence polarization applications.
Compact multimode reader for 6- to 384-well microplates and Take3 microvolume plates. The unique dual optics design provides superior performance for UV-Vis absorbance, fluorescence, luminescence, and AlphaScreen/AlphaLISA workflows. With incubation and shaking, plus a dual reagent injector module, the system will meet all your assay requirements now and in the future. Synergy HTX is controlled by the easy-to-use, yet powerful, Gen5 software for data collection, analysis, exporting, and reporting.
Modular multimode microplate reader, with monochromator-based optics and filter-based optics for fluorescence and luminescence detection, plus filter-free UV-Vis absorbance. Hybrid is the term that Agilent BioTek uses to describe the unique optical systems available for Synergy H1 multimode readers. Each of these readers is configurable to include filter-based or monochromator-based optics for fluorescence and luminescence detection, or they can include both filter- and monochromator-based optics for maximum assay flexibility, sensitivity, and specificity. The bandwidth can be set between 9 and 50 nm, in 1 nm increments, to fully optimize reader settings for best sensitivity and specificity compared to fixed bandwidth systems. Comes with Gen5 Data Analysis Software.
Automated multi-mode reagent dispenser for 6- to 1536-well microplates.
Microscope that enables augmented microscopy, which fully automates image capture, processing and analysis.
Microscope that offers up to 60x air; 60x and 100x oil immersion magnification, with fluorescence, brightfield, color brightfield, and phase contrast channels for maximum application reach.
Microplate reader that includes several models with options that meet specific needs of research and OEM users. Top and bottom reading are available to read anything from 6 well to 384 well microplates, and PCR plates. Optional external dispenser module allows running applications such as ion channel assays and flash luminescence assays.
Microarray that is used for printing DNA, proteins, or other biological samples. It has modular component design and software for microruns or unattended highthroughput prints.
Spectrophotometer that offers filter free, wide wavelength range for UV-Vis absorbance measurements in variety of microplate formats, and in 2 uL samples when available Take3 plate is used.
Spectrophotometer that is used for UV-Vis measurements in 6- to 384-well microplates, cuvettes and in micro-volume samples with the available Take3 Micro-Volume Plate. Endpoint, kinetic, spectral scanning and well area scanning modes, plus incubation and shaking enable wide-ranging applications.
Microplate washer that is designed to rapidly wash 96 or 384 well microplates. Keypad interface has independent control of plate position during dispense and aspiration cycles, as well as fully programmable fluid volumes and flow rates, shaking, and soaking.
Microplate washer that aspirates and dispenses into 96- and 384-well plates.
MyiQ Single Color Real Time PCR Detection System builds on the strengths of the iCycler Thermal Cycler, which provides the optimum performance for PCR. The MyiQ system features a tungsten halogen lamp as the light source. The filter-based optical design allows the use of optimal wavelengths of light for excitation and emission, resulting in excellent sensitivity and discrimination between multiple fluorophores. The CCD detector captures a simultaneous image of all 96 wells. This results in a comprehensive data set illustrating the kinetic behavior of the data during each cycle. Simultaneous image collection insures that well-to-well data may reliably be compared. The MyiQ system reports data on the PCR in progress in real time, allowing immediate feedback on reaction success. All of these features demonstrate that the MyiQ system hardware was built to promote reliability and flexibility. The MyiQ software includes features that make software easy and useful. The software is designed for offering speedy setup and analytical results. Many functions are presented graphically for ease of use. Tips on usage are available as your mouse rolls over the buttons. In addition, the Online Help Manual is available at all times simply by pressing the F1 key. The MyiQ software automatically analyzes the collected data at the touch of a button, yet leaves room for additional optimization of results based on your analysis preferences.
Microplate washer that is equipped for full plate washing along with three reagent dispensers in one and includes washing and dispensing for standard assays, biomagnetic separation and vacuum filtration protocols.
Microplate stacker compatible with BioTek's washers, dispensers, detectors and imaging systems and accommodates assay workflows for 96- and 384-well plates.