Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

This service exclusively searches for literature that cites resources. Please be aware that the total number of searchable documents is limited to those containing RRIDs and does not include all open-access literature.

Search

Type in a keyword to search

On page 1 showing 1 ~ 1 papers out of 1 papers

Abnormal left atrial body stiffness is predicted by appendage size: impact of appendage occlusion on left atrial mechanics assessed by pressure-volume analysis.

  • Alda Bregasi‎ et al.
  • American journal of physiology. Heart and circulatory physiology‎
  • 2022‎

Atrial cardiomyopathy has been recognized as having important consequences for cardiac performance and clinical outcomes. The pathophysiological role of the left atrial (LA) appendage and the effect of percutaneous left atrial appendage occlusion (LAAO) upon LA mechanics is incompletely understood. We evaluated if changes in LA stiffness due to endocardial LAAO can be detected by LA pressure-volume (PV) analysis and whether stiffness parameters are associated with baseline characteristics. Patients undergoing percutaneous endocardial LAAO (n = 25) were studied using a novel PV analysis using near-simultaneous three-dimensional LA volume measurements by transesophageal echocardiography (TEE) and direct invasive LA pressure measurements. LA stiffness (dP/dV, change in pressure with change in volume) was calculated before and after LAAO. Overall LA stiffness significantly increased after LAAO compared with baseline (median, 0.41-0.64 mmHg/mL; P ≪ 0.001). LA body stiffness after LAAO correlated with baseline LA appendage size by indexed maximum depth (Spearman's rank correlation coefficient Rs = 0.61; P < 0.01). LA stiffness change showed an even stronger correlation with baseline LA appendage size by indexed maximum depth (Rs = 0.70; P < 0.001). We found that overall LA stiffness increases after endocardial LAAO. Baseline LA appendage size correlates with the magnitude of increase and LA body stiffness. These findings document alteration of LA mechanics after endocardial LAAO and suggest that the LA appendage modulates overall LA compliance.NEW & NOTEWORTHY Our study documents a correlation of LA appendage remodeling with the degree of chronically abnormal LA body stiffness. In addition, we found that LA appendage size was the baseline parameter that best correlated with the magnitude of a further increase in overall LA stiffness after appendage occlusion. These findings offer insights about the LA appendage and LA mechanics that are relevant to patients at risk for adverse atrial remodeling, especially candidates for LA appendage occlusion.


  1. SciCrunch.org Resources

    Welcome to the FDI Lab - SciCrunch.org Resources search. From here you can search through a compilation of resources used by FDI Lab - SciCrunch.org and see how data is organized within our community.

  2. Navigation

    You are currently on the Community Resources tab looking through categories and sources that FDI Lab - SciCrunch.org has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.

  3. Logging in and Registering

    If you have an account on FDI Lab - SciCrunch.org then you can log in from here to get additional features in FDI Lab - SciCrunch.org such as Collections, Saved Searches, and managing Resources.

  4. Searching

    Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:

    1. Use quotes around phrases you want to match exactly
    2. You can manually AND and OR terms to change how we search between words
    3. You can add "-" to terms to make sure no results return with that term in them (ex. Cerebellum -CA1)
    4. You can add "+" to terms to require they be in the data
    5. Using autocomplete specifies which branch of our semantics you with to search and can help refine your search
  5. Save Your Search

    You can save any searches you perform for quick access to later from here.

  6. Query Expansion

    We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.

  7. Collections

    If you are logged into FDI Lab - SciCrunch.org you can add data records to your collections to create custom spreadsheets across multiple sources of data.

  8. Facets

    Here are the facets that you can filter your papers by.

  9. Options

    From here we'll present any options for the literature, such as exporting your current results.

  10. Further Questions

    If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.

Publications Per Year

X

Year:

Count: