Mathematical Models for the Skin to Lumbosacral Epidural Distance in Dogs: A Cadaveric Computed-Tomography Study.

Animals : an open access journal from MDPI | 2021

This study aimed to validate previously published computed tomography (CT) derived mathematical equations with the true skin to lumbosacral epidural distance (SLED) in dog cadavers. Phase 1: The lumbar region of 11 dog cadavers were scanned in sternal recumbency to determine the effect of cranial, neutral, and caudal pelvic limb positioning on the CT derived lumbosacral epidural distance (CLED). Phase 2: The epidural space was determined using contrast epidurography, and the SLED was analysed against the mathematical equations using a body condition score (BCS) and either the cadaveric occipital-coccygeal length (OCL) (Equation (1): = 7.3 + 0.05*OCL + 16.45*BCS) or the ilium wing distance (IWD) (Equation (2): = 3.5 + 0.56*IWD + 16.6*BCS). There were no differences detected between the pelvic limb positions and the CLED. Both equations demonstrated strong correlations (Equation (1): r = 0.7196; Equation (2): r = 0.7590) with the SLED. The level of agreement was greater for Equation (1) than with Equation (2) (concordance coefficient 0.6061 and 0.3752, respectively). Equation (1) also demonstrated a closer fit to the concordance line compared with Equation (2) (bias correction factor 0.8422 and 0.4960, respectively). Further studies in live anaesthetised dogs will help to determine the usefulness of the pre-procedural knowledge when performing lumbosacral epidurals.

Pubmed ID: 34679993 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Microsoft Excel (tool)

RRID:SCR_016137

Software application with data analysis tools and spreadsheet templates to track and visualize data. It is used to manage and process data.

View all literature mentions