Ultratrace Detection of Nickel(II) Ions in Water Samples Using Dimethylglyoxime-Doped GQDs as the Induced Metal Complex Nanoparticles by a Resonance Light Scattering Sensor.

ACS omega | 2021

This study aimed to synthesize dimethylglyoxime (DMG) (N-source)-doped graphene quantum dots (N-GQDs) via simultaneous pyrolysis of citric acid and 1.0% (w/v) DMG. The maximum excitation wavelength (λmax, ex = 380 nm) of the N-GQD solution (49% quantum yield (QY)) was a red shift with respect to that of bare GQDs (λmax, ex = 365 nm) (46% QY); at the same maximum emission wavelength (λmax, em = 460 nm), their resonance light scattering (RLS) intensity peak was observed at λmax, ex/em = 530/533 nm. FTIR, X-ray photoelectron spectroscopy, XRD, energy-dispersive X-ray spectroscopy, and transmission electron microscopy analyses were performed to examine the synthesized materials. The selective and sensitive detection of Ni2+ using the RLS intensity was performed at 533 nm under the optimum conditions consisting of both 25 mg L-1 N-GQDs and 2.5 mg L-1 DMG in the ammonium buffer solution of pH 9.0. The linearity of Ni2+ was 50.0-200.0 μg L-1 with a regression line, y = 5.031x - 190.4 (r 2 = 0.9948). The limit of detection (LOD) and the limit of quantitation (LOQ) were determined to be 20.0 and 60.0 μg L-1, respectively. The method precision expressed as % RSDs was 4.90 for intraday (n = 3 × 3) and 7.65 for interday (n = 5 × 3). This developed method afforded good recoveries of Ni2+ in a range of 85-108% when spiked with real water samples. Overall, this innovative method illustrated the identification and detection of Ni2+ as a DMG complex with N-GQDs, and the detection was highly sensitive and selective.

Pubmed ID: 34151061 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Millipore (tool)

RRID:SCR_008983

An Antibody supplier

View all literature mentions

Sigma-Aldrich (tool)

RRID:SCR_008988

American chemical, life science and biotechnology company owned by Merck KGaA. Merger of Sigma Chemical Company and Aldrich Chemical Company. Provides organic and inorganic chemicals, building blocks, reagents, advanced materials and stable isotopes for chemical synthesis, medicinal chemistry and materials science, antibiotics, buffers, carbohydrates, enzymes, forensic tools, hematology and histology, nucleotides, proteins, peptides, amino acids and their derivatives.

View all literature mentions