Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

Poincaré Plot Area of Gamma-Band EEG as a Measure of Emergence From Inhalational General Anesthesia.

Frontiers in physiology | 2021

The Poincaré plot obtained from electroencephalography (EEG) has been used to evaluate the depth of anesthesia. A standalone EEG Analyzer application was developed; raw EEG signals obtained from a bispectral index (BIS) monitor were analyzed using an on-line monitoring system. Correlations between Poincaré plot parameters and other measurements associated with anesthesia depth were evaluated during emergence from inhalational general anesthesia. Of the participants, 20 were adults anesthetized with sevoflurane (adult_S E V ), 20 were adults anesthetized with desflurane (adult_D E S ), and 20 were pediatric patients anesthetized with sevoflurane (ped_S E V ). EEG signals were preprocessed through six bandpass digital filters (f0: 0.5-47 Hz, f1: 0.5-8 Hz, f2: 8-13 Hz, f3: 13-20 Hz, f4: 20-30 Hz, and f5: 30-47 Hz). The Poincaré plot-area ratio (PPAR = PP A_fx /PP A_f0 , fx = f1∼f5) was analyzed at five frequency ranges. Regardless of the inhalational anesthetic used, there were strong linear correlations between the logarithm of PP AR at f5 and BIS (R 2 = 0.67, 0.79, and 0.71, in the adult_S E V , adult_D E S , and ped_S E V groups, respectively). As an additional observation, a part of EMG activity at the gamma range of 30-47 Hz probably influenced the calculations of BIS and PP AR_f5 with a non-negligible level. The logarithm of PPAR in the gamma band was most sensitive to state changes during the emergence process and could provide a new non-proprietary parameter that correlates with changes in BIS during measurement of anesthesia depth.

Pubmed ID: 33633587 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Medtronic (tool)

RRID:SCR_003988

Medical technology company that develops and manufactures devices and therapies to treat more than 30 chronic diseases, including heart failure, Parkinson's disease, urinary incontinence, Down syndrome, obesity, chronic pain, spinal disorders, and diabetes. A Commercial healthcare organization for both patients and healthcare professionals. For professionals, it provides products, therapy and procedure solutions, and services.

View all literature mentions

Microsoft Excel (tool)

RRID:SCR_016137

Software application with data analysis tools and spreadsheet templates to track and visualize data. It is used to manage and process data.

View all literature mentions