Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

0.999. The accuracy varied from 95.4 to 107.4%, while the intra- and inter-day precision RSD values were 0.7-10.6% and 1.7-12.2%, respectively. Recoveries were within the range of 61.1-93.3%, and matrix effects were in the range of 19.1-102.6%. The validated method was successfully applied to the identification and quantification of 5F-MDMB-PICA and its metabolites in hair from authentic forensic cases." />

Detection of a New Tert-Leucinate Synthetic Cannabinoid 5F-MDMB-PICA and Its Metabolites in Human Hair: Application to Authentic Cases.

Frontiers in chemistry | 2020

Methyl 2 -[ [ 1- (5- fluoropentyl) indole - 3- carbonyl] amino] -3, 3- dimethyl - butanoate (5F-MDMB-PICA) is a new synthetic cannabinoid characterized by valinate or tert-leucinate moieties. In recent years, 5F-MDMB-PICA has been abused in the form of "spice-like" herbal incenses or electronic cigarette oil. A UHPLC-MS/MS method was developed to detect 5F-MDMB-PICA and its metabolites in human hair. Approximately 20 mg of hair was weighed and pulverized with methanol below 4°C. After ultrasonication, centrifugation and filtration, 200 μL of supernatant was placed into an autosampler vial and analyzed on a Waters Acquity UPLC HSS T3 column (100 mm × 2.1 mm, 1.8 μm particle size) using an acetonitrile-20 mmol/L ammonium acetate (0.1% formic acid, 5% acetonitrile) gradient with a run time of 8 min. The limit of detection (LOD) ranged from 0.5 to 5 pg/mg, and the lower limit of quantitation (LLOQ) ranged from 1 to 5 pg/mg. The method was shown to be linear over a concentration range of 1-200 pg/mg. The linear correlation (R 2) of the calibration curves for all analytes was >0.999. The accuracy varied from 95.4 to 107.4%, while the intra- and inter-day precision RSD values were 0.7-10.6% and 1.7-12.2%, respectively. Recoveries were within the range of 61.1-93.3%, and matrix effects were in the range of 19.1-102.6%. The validated method was successfully applied to the identification and quantification of 5F-MDMB-PICA and its metabolites in hair from authentic forensic cases.

Pubmed ID: 33330406 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Sigma-Aldrich (tool)

RRID:SCR_008988

American chemical, life science and biotechnology company owned by Merck KGaA. Merger of Sigma Chemical Company and Aldrich Chemical Company. Provides organic and inorganic chemicals, building blocks, reagents, advanced materials and stable isotopes for chemical synthesis, medicinal chemistry and materials science, antibiotics, buffers, carbohydrates, enzymes, forensic tools, hematology and histology, nucleotides, proteins, peptides, amino acids and their derivatives.

View all literature mentions