Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

A novel data processing method CyC* for quantitative real time polymerase chain reaction minimizes cumulative error.

PloS one | 2019

Quantitative real-time polymerase chain reaction (qPCR) is routinely conducted for DNA quantitative analysis using the cycle-threshold (Ct) method, which assumes uniform/optimum template amplification. In practice, amplification efficiencies vary from cycle to cycle in a PCR reaction, and often decline as the amplification proceeds, which results in substantial errors in measurement. This study reveals the cumulative error for quantification of initial template amounts, due to the difference between the assumed perfect amplification efficiency and actual one in each amplification cycle. The novel CyC* method involves determination of both the earliest amplification cycle detectable above background ("outlier" C*) and the amplification efficiency over the cycle range from C* to the next two amplification cycles; subsequent analysis allows the calculation of initial template amount with minimal cumulative error. Simulation tests indicated that the CyC* method resulted in significantly less variation in the predicted initial DNA level represented as fluorescence intensity F0 when the outlier cycle C* was advanced to an earlier cycle. Performance comparison revealed that CyC* was better than the majority of 13 established qPCR data analysis methods in terms of bias, linearity, reproducibility, and resolution. Actual PCR test also suggested that relative expression levels of nine genes in tea leaves obtained using CyC* were much closer to the real value than those obtained with the conventional 2-ΔΔCt method. Our data indicated that increasing the input of initial template was effective in advancing emergence of the earliest amplification cycle among the tested variants. A computer program (CyC* method) was compiled to perform the data processing. This novel method can minimize cumulative error over the amplification process, and thus, can improve qPCR analysis.

Pubmed ID: 31185064 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


GenBank (tool)

RRID:SCR_002760

NIH genetic sequence database that provides annotated collection of all publicly available DNA sequences for almost 280 000 formally described species (Jan 2014) .These sequences are obtained primarily through submissions from individual laboratories and batch submissions from large-scale sequencing projects, including whole-genome shotgun (WGS) and environmental sampling projects. Most submissions are made using web-based BankIt or standalone Sequin programs, and GenBank staff assigns accession numbers upon data receipt. It is part of International Nucleotide Sequence Database Collaboration and daily data exchange with European Nucleotide Archive (ENA) and DNA Data Bank of Japan (DDBJ) ensures worldwide coverage. GenBank is accessible through NCBI Entrez retrieval system, which integrates data from major DNA and protein sequence databases along with taxonomy, genome, mapping, protein structure and domain information, and biomedical journal literature via PubMed. BLAST provides sequence similarity searches of GenBank and other sequence databases. Complete bimonthly releases and daily updates of GenBank database are available by FTP.

View all literature mentions

Thermo Fisher Scientific (tool)

RRID:SCR_008452

Commercial vendor and service provider of laboratory reagents and antibodies. Supplier of scientific instrumentation, reagents and consumables, and software services.

View all literature mentions