Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

Validation of beat by beat fetal heart signals acquired from four-channel fetal phonocardiogram with fetal electrocardiogram in healthy late pregnancy.

Scientific reports | 2018

Fetal heart rate monitoring is an essential obstetric procedure, however, false-positive results cause unnecessary obstetric interventions and healthcare cost. In this study, we propose a low cost and non-invasive fetal phonocardiography based signal system to measure the fetal heart sounds and fetal heart rate. Phonocardiogram (PCG) signals contain acoustic information reflecting the contraction and relaxation of the heart. We have developed a four-channel recording device with four separated piezoelectric sensors harnessed by a cloth sheet to record abdominal phonogram signals. A multi-lag covariance matrix based eigenvalue decomposition technique was used to extract fetal and maternal heart sounds as well as maternal breathing movement. In order to validate the fetal heart sounds extracted by PCG signal processing, 10 minutes' simultaneous recordings of fetal Electrocardiogram (fECG) and abdominal phonogram from 15 pregnant women (27 ± 5-year-old) with fetal gestation ages between 33 and 40 weeks were obtained and processed. Highly significant (p < 0.01) correlation (r = 0.96; N = 270) was found between beat to beat fetal heart rate (FHRECG) from fECG and the same (FHRPCG) from fetal PCG signals. Bland-Altman plot of FHRECG and FHRPCG shows good agreement (<5% difference). We conclude that the proposed beat to beat fetal heart rate measurement system would be useful for monitoring fetal neurological wellbeing as a better alternative to traditional cardiotocogram based antenatal fetal heart rate monitoring.

Pubmed ID: 30206289 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


GE Healthcare (tool)

RRID:SCR_000004

A commercial antibody supplier and provider of various services.

View all literature mentions