Functional and electrophysiological changes after graded traumatic spinal cord injury in adult rat.

Experimental neurology | 2005

A graded contusion spinal cord injury (SCI) was created in the adult rat spinal cord using the Infinite Horizons (IH) impactor to study the correlation between injury severity and anatomical, behavioral, and electrophysiological outcomes. Adult Fisher rats were equally divided into five groups and received contusion injuries at the ninth thoracic level (T9) with 100, 125, 150, 175, or 200 kdyn impact forces, respectively. Transcranial magnetic motor-evoked potentials (tcMMEPs) and BBB open-field locomotor analyses were performed weekly for 4 weeks postinjury. Our results demonstrated that hindlimb locomotor function decreased in accordance with an increase in injury severity. The locomotor deficits were proportional to the amount of damage to the ventral and lateral white matter (WM). Locomotor function was strongly correlated to the amount of spared WM, which contains the reticulospinal and propriospinal tracts. Normal tcMMEP latencies were recorded in control, all of 100-kdyn-injured and half of 125-kdyn-injured animals. Delayed latency responses were recorded in some of 125-kdyn-injured and all of 150-kdyn-injured animals. No tcMMEP responses were recorded in 175- and 200-kdyn-injured animals. Comparison of tcMMEP responses with areas of WM loss or demyelination identified the medial ventrolateral funiculus (VLF) as the location of the tcMMEP pathway. Immunohistochemical and electromicroscopic (EM) analyses showed the presence of demyelinated axons in WM tracts surrounding the lesion cavities at 28 days postinjury. These data support the notion that widespread WM damage in the ventral and lateral funiculi may be a major cause for locomotor deficits and lack of tcMMEP responses after SCI.

Pubmed ID: 15629760 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

  • Agency: NINDS NIH HHS, United States
    Id: NS38665
  • Agency: NCRR NIH HHS, United States
    Id: RR15576

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


Neurolucida (tool)

RRID:SCR_001775

Neurolucida is advanced scientific software for brain mapping, neuron reconstruction, anatomical mapping, and morphometry. Since its debut more than 20 years ago, Neurolucida has continued to evolve and has become the worldwide gold-standard for neuron reconstruction and 3D mapping. Neurolucida has the flexibility to handle data in many formats: using live images from digital or video cameras; stored image sets from confocal microscopes, electron microscopes, and scanning tomographic sources, or through the microscope oculars using the patented LucividTM. Neurolucida controls a motorized XYZ stage for integrated navigation through tissue sections, allowing for sophisticated analysis from many fields-of-view. Neurolucidas Serial Section Manager integrates unlimited sections into a single data file, maintaining each section in aligned 3D space for full quantitative analysis. Neurolucidas neuron tracing capabilities include 3D measurement and reconstruction of branching processes. Neurolucida also features sophisticated tools for mapping delineate and map anatomical regions for detailed morphometric analyses. Neurolucida uses advanced computer-controlled microscopy techniques to obtain accurate results and speed your work. Plug-in modules are available for confocal and MRI analysis, 3D solid modeling, and virtual slide creation. The user-friendly interface gives you rapid results, allowing you to acquire data and capture the full 3D extent of neurons and brain regions. You can reconstruct neurons or create 3D serial reconstructions directly from slides or acquired images, and Neurolucida offers full microscope control for brightfield, fluorescent, and confocal microscopes. Its added compatibility with 64-bit Microsoft Vista enables reconstructions with even larger images, image stacks, and virtual slides. Adding the Solid Modeling Module allows you to rotate and view your reconstructions in real time. Neurolucida is available in two separate versions Standard and Workstation. The Standard version enables control of microscope hardware, whereas the Workstation version is used for offline analysis away from the microscope. Neurolucida provides quantitative analysis with results presented in graphical or spreadsheet format exportable to Microsoft Excel. Overall, features include: - Tracing Neurons - Anatomical Mapping - Image Processing and Analysis Features - Editing - Morphometric Analysis - Hardware Integration - Cell Analysis - Visualization Features Sponsors: Neurolucida is supported by MBF Bioscience.

View all literature mentions