X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

Resource Name
RRID:SCR_010482 RRID Copied      
PDF Report How to cite
COBRE (RRID:SCR_010482)
Copy Citation Copied
Resource Information

URL: http://fcon_1000.projects.nitrc.org/indi/retro/cobre.html

Proper Citation: COBRE (RRID:SCR_010482)

Description: Data set of raw anatomical and functional MR data from 72 patients with Schizophrenia and 75 healthy controls (ages ranging from 18 to 65 in each group). All subjects were screened and excluded if they had: history of neurological disorder, history of mental retardation, history of severe head trauma with more than 5 minutes loss of consciousness, history of substance abuse or dependence within the last 12 months. Diagnostic information was collected using the Structured Clinical Interview used for DSM Disorders (SCID). A multi-echo MPRAGE (MEMPR) sequence was used with the following parameters: TR/TE/TI = 2530/(1.64, 3.5, 5.36, 7.22, 9.08)/900 ms, flip angle = 7��, FOV = 256x256 mm, Slab thickness = 176 mm, Matrix = 256x256x176, Voxel size =1x1x1 mm, Number of echos = 5, Pixel bandwidth =650 Hz, Total scan time = 6 min. With 5 echoes, the TR, TI and time to encode partitions for the MEMPR are similar to that of a conventional MPRAGE, resulting in similar GM/WM/CSF contrast. Rest data was collected with single-shot full k-space echo-planar imaging (EPI) with ramp sampling correction using the intercomissural line (AC-PC) as a reference (TR: 2 s, TE: 29 ms, matrix size: 64x64, 32 slices, voxel size: 3x3x4 mm3). Slice Acquisition Order: Rest scan - collected in the Axial plane - series ascending - multi slice mode - interleaved MPRAGE - collected in the Sag plane - series interleaved - multi slice mode - single shot The following data are released for every participant: * Resting fMRI * Anatomical MRI * Phenotypic data for every participant including: gender, age, handedness and diagnostic information.

Abbreviations: COBRE

Synonyms: Center for Biomedical Research Excellence, Center for Biomedical Research Excellence (COBRE)

Resource Type: data set, data or information resource

Keywords: resting fmri, anatomical mri, phenotype, gender, age, handedness, diagnosis, adult human, fmri, mri, neuroimaging, mental state assessment, clinical

Expand All
Usage and Citation Metrics

We found {{ ctrl2.mentions.total_count }} mentions in open access literature.

We have not found any literature mentions for this resource.

We are searching literature mentions for this resource.

Most recent articles:

{{ mention._source.dc.creators[0].familyName }} {{ mention._source.dc.creators[0].initials }}, et al. ({{ mention._source.dc.publicationYear }}) {{ mention._source.dc.title }} {{ mention._source.dc.publishers[0].name }}, {{ mention._source.dc.publishers[0].volume }}({{ mention._source.dc.publishers[0].issue }}), {{ mention._source.dc.publishers[0].pagination }}. (PMID:{{ mention._id.replace('PMID:', '') }})

Checkfor all resource mentions.

Collaborator Network

A list of researchers who have used the resource and an author search tool

Find mentions based on location


{{ ctrl2.mentions.errors.location }}

A list of researchers who have used the resource and an author search tool. This is available for resources that have literature mentions.

Ratings and Alerts

No rating or validation information has been found for COBRE.

No alerts have been found for COBRE.

Data and Source Information