We support boolean queries, use +,-,<,>,~,* to alter the weighting of terms
decrease miR547-5p
miRNA Agomir-NC
increase miR547-5p
knock down control
knock down IL-33
Dual luciferase reporter assay
Dual luciferase reporter assay
Dual luciferase reporter assay
Dual luciferase reporter assay
Dual luciferase reporter assay
Dual luciferase reporter assay
Real time PCR
Real time PCR
real time PCR
Software R package for computing and annotating genomic ranges. Used for storing and manipulating genomic intervals and variables defined along genome.
Fluorescence activated cell sorting instrument by BD Biosciences. Flow cytometer as high speed fixed alignment benchtop cell sorter. Cytometer can be operated at varied pressures and can acquire up to 70,000 events per second. Enables multicolor analysis of up to 13 fluorescent markers and two scatter parameters at time., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
The simulator art_illumina function in ART was applied to generate simulated RNA-Seq data. Using the RNA-Seq reads in normal pulmonary microvascular endothelial cells from the National Center for Biotechnology Information (NCBI) Sequence Read Archive (SRA) database SRR349695 as the background, we plugged the simulated fusion reads into the background reads. Two types of fusion reads were designed, with the first one from the linear transcripts and the second one from the linear and circular pooled transcripts. Different sequencing coverage including 20X, 50X, 100X, each with two read lengths of 50 bp and 100 bp were designed in the simulated data. It was designed as the benchmark data for fusion RNA and fusion-circ RNA identification.
Spectrophotometer for measurement and analysis of 1 ul samples. Performs measuring of 1 ul samples with high accuracy and reproducibility. Full spectrum from 220nm to 750nm spectrophotometer utilizes patented sample retention technology that employs surface tension alone to hold sample in place. No need for cuvettes. Has capability to measure highly concentrated samples without dilution.
The cytoskeleton consists of three types of cytosolic fibers: microtubules, microfilaments (actin filaments), and intermediate filaments. Globular tubulin subunits comprise the microtubule building block, with α/β-tubulin heterodimers forming the tubulin subunit common to all eukaryotic cells. γ-tubulin is required to nucleate polymerization of tubulin subunits to form microtubule polymers. Many cell movements are mediated by microtubule action, including the beating of cilia and flagella, cytoplasmic transport of membrane vesicles, chromosome alignment during meiosis/mitosis, and nerve-cell axon migration. These movements result from competitive microtubule polymerization and depolymerization or through the actions of microtubule motor proteins (1).