Microwave sample preparation device system designed to count and size particles individually. It can used for in service oil samples with only 4 mL of 10 times diluted samples.
Benchtop liquid scintillation analyzer that detects small amounts of alpha, beta, and gamma radioactivity. Time resolved liquid scintillation counting is used for low background counting of LS samples., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Gamma counter available in single, five, or ten detector configurations. Can count RIA tubes, 16x100mm and variety of smaller micro tubes using available adapter.This instrument has dot Matrix Printer, tube racks, and protocol ID tags.Single detector model is available in 2 inch or 3 inch crystal configurations for research grade capabilities.
Laboratory microwave system that includes True Variable Wattage, water recirculation system, temperature restrictive temperature probe, RS232 Port, Cable and Software, Programmable times, Four intermittent power settings, Magnetron prewarming, Air Bubbler, and Vacuum Cycling. System has precision temperature control and monitoring for microwave assisted processing of tissue. Can be used for formalin fixation, decalcification, special stains, immunocytochemistry and complete processing of tissue into paraffin.
Intravital laser scanning microscope for small animal imaging with up to four lasers 488nm, 561nm, 633nm, and 748nm. Able to image multiple fluorescence probes simultaneously. Scan head has tilting capability to image objective orientation in three dimensions.Three magnifications of MicroProbe lenses enable to capture either large field of view or high resolution images on living animal. Certain conventional microscope objectives can also be used on IV100 as well.
Microscope equipped with CFI60 infinity optical system, providing images in all applications. Incorporates specifications adopted for CFI60 series objectives, including 60 millimeter parfocal distance, 25 millimeter thread size, and standard 22 millimeter field of view. Main components of CFI60 infinity optical system include objective, tube lens to converge light beam, and eyepiece lens to enlarge intermediate image. Fluorescence microscope that has detachable substage, 12 volt 100 watt tungsten halide lamp, filter magazine, and choice of sextuple nosepiece or sextuple DIC nosepiece.Has objectives for brightfield, darkfield, Nomarski DIC, epi fluorescence, or phase contrast techniques.
SMZ1500 stereoscopic zoom microscope is system with apochromatic objectives, zoom ratio of 15 to 1, range of magnifications from 0.75x to 11.25x for total magnifying capability of 3.75x up to 540x, and is best for in depth imaging.Zoom knob allows to zoom from 1x to 11x at 1x-intervals without interrupting observations. Other facets include high eyepoint eyepieces with built-in diopter adjustments, wide field of view, and built-in aperture diaphragm for achieving optimal depth of focus and improved photomicrography.Provides options of either low eye-level viewing tube or tilting eyepiece tube, with or without eye-level risers. Three different diascopic stands with built-in power supplies may also be utilized with instrument, or standard stand that features low profile for increased clearance.
Inverted fluorescence tissue culture microscope capable of imaging specimens in brightfield, darkfield, phase contrast, Hoffman modulation contrast, fluorescence, and differential interference contrast modes.TIRFM-IX illuminator is this microscope accessory which attaches to the rear lamphouse port and contains FC connector for external laser source and port for mercury or xenon lamp housing.
Nikon Instruments AZ100 C1si is macro confocal microscope system combining stereo and compound microscopes into single hybrid imaging system for dynamic imaging of single cells or whole specimens.System covers range of magnifications from 5x to 400x. Has triple nosepiece that can switch magnifications. AZ100 C1si boasts simultaneous 32 channel spectral image acquisition over spectral range of 320 nm in single scan. Simultaneous 32 channel acquisition at 10 nm, 5 nm or 2.5 nm bandwidths, all software controlled, is possible.
Thermocycler that operates with 96 well and 60 well microplates. Has temperature configurations from 0 C to 105 C and pressure and height adjustment via thumbwheel. Comes with 14 pre-programmed protocols.
Microvolume UV Vis spectrophotometer for nucleic acid and protein quantification that can measure multiple samples using 1 to 2 uL of samples. Can analyze spectrum of 220nm to 750nm and measure 96 samples in less than six minutes. Can measure multiple samples in one measurement cycle, up to eight samples at one time. Has single sample mode. Can analyze the full spectrum from 220 to 750nm and calculates sample purity ratios 260/280.
Sample disruption instrument that can homogenize, grind, or lyse biological samples. Samples are added to individual lysing matrix tubes and shaken in tridimensional motion.
Microplate reader that can read one sample or up to 384 in single plate read using any standard cuvette, 12 x 75 mm test tube, or 96 or 384 well microplate. It can run standard spectrophotometer and microplate reader applications.
Nuclear imager for quantitative 3D functional imaging of SPECT tracers down to 0.12 mm ex vivo and 0.25 mm in vivo. Used for quantitative sub mm imaging of higher energy and theranostic isotopes such as 131I, 188Re, 213Bi, 225Ac, and 223Ra.
Benchtop manager cell sorter for cell isolation in automated workflows. Sorts cells directly from whole blood or bone marrow without density gradient centrifugation or erythrocyte lysis.
Electronic microtome cryostat upright standing with open top working area that can cut temperature to negative 35 degrees Celsius. Equipped with automatic 24 hour defroster with interrupt key and handwheel brake.Provides protection for knife and specimen as it retracts specimen at the end of the cut. Motorized coarse feed system allows sample to be moved forward and backward.Two knife carriers are available. Standard knife carrier is for knives to be easily clamped in place and adjusted, and the disposable blade holder EC for high- and low-profile blades.
Differential scanning calorimeter for study of samples in solution. It measures intramolecular stability of proteins, nucleic acids, oligomeric proteins, nucleic acid duplexes, lipid and detergent micellar system.
LabChip GXII Touch is a protein characterization system that provides reproducible quantitation, molecular weight sizing and percent purity analysis of protein samples. Leveraging microfluidic electrophoretic separation technology, the LabChip GXII Touch system enables rapid characterization with minimal sample preparation setup and sample input volume.
Miligram balance that is used for weighing, tarring, percent weighing, and dynamic weighing for unstable samples. Has maximum capacity of 310 grams. Lab balance utilizes mono block weighing technology with permanent shock protection and built in overload protection as well as automatic calibration.
Invitrogen benchtop automated cell counter. Can perform cell counts, viability calculations, hemocytometry, fluorescent protein expression, and measure fluorescence capabilities. There are also reusable slides, fluorescence capabilities, and brightfield fluorescence channels.