We support boolean queries, use +,-,<,>,~,* to alter the weighting of terms
Developed for generation of single cell suspensions from murine and rat skeletal muscle tissue. It is optimized for high yield of viable cells, for example satellite cells, while preserving important cell surface epitopes. Mature myotubes will be destroyed.
Dissociator is a benchtop instrument for the semi-automated dissociation of tissues into single-cell suspensions or thorough homogenates. A single sample or two samples in parallel can be processed. Two types of gentleMACS Tubes used with the instrument enable the time-saving and easy dissociation or homogenization of tissues in a closed system. The instrument offers optimized gentleMACS Programs for a variety of specific applications. Special protocols have been developed for various tissues. The standardized tissue dissociation or homogenization procedures make for and reproducible results. For higher throughput and even more flexibility see also the gentleMACS Octo Dissociator. For fully automated tissue dissociation browse the gentleMACS Octo Dissociator with Heaters
Developed for specific removal of myelin debris from single cell suspensions. Myelin Removal Beads II work without determination of cell number or myelin debris cell ratio.
Allows for generation of single cell suspensions from human umbilical cord. It is not certified GMP product, but has been specifically developed to enable quality control of frozen umbilical cord samples for umbilical cord tissue banks by detecting mesenchymal stem cells, MSCs, directly after dissociation by flow cytometry without long term culture of cells.
Enables generation of single cell suspensions from human skin tissue without separating dermis and epidermis. Kit has been developed for isolation of fibroblasts from diverse human skin biopsies as well as for phenotyping or enumeration of human skin cell populations by flow cytometry.
Developed for generation of single cell suspensions from human tumor tissue. Kit is optimized for high yield of tumor cells and tumor infiltrating lymphocytes, while preserving important cell surface epitopes.
Developed for standardized and reproducible dissociation of in vitro generated EBs or pluripotent stem cell derived neurospheres. Optimized for high yields, cell viability, and reproducibility.
Optimized for generation of single cell suspensions from human formalin fixed paraffin embedded, FFPE, carcinoma sections. High yield of single cellscanbe obtained, while preserving important cell epitopes cytokeratin for cell analysis of carcinoma cells and vimentin for non carcinoma cells.
Enables generation of single cell suspensions from human epidermal tissue. Kit has been particularly developed for isolation of keratinocytes from diverse human skin biopsies.
Tool for removal of endotoxin and DNA from purified protein preparations.
Developed specifically for tissue dissociation of human and mouse brain tumors, such as glioblastoma, multiforme, or medulloblastoma.
Nuclear imager for quantitative 3D functional imaging of SPECT tracers down to 0.12 mm ex vivo and 0.25 mm in vivo. Used for quantitative sub mm imaging of higher energy and theranostic isotopes such as 131I, 188Re, 213Bi, 225Ac, and 223Ra.
Benchtop manager cell sorter for cell isolation in automated workflows. Sorts cells directly from whole blood or bone marrow without density gradient centrifugation or erythrocyte lysis.
Isothermal titration calorimeter for label free, in solution, study of biomolecular interactions. It delivers measurement of binding parameters with minimum of 10 ug sample.
Electronic microtome cryostat upright standing with open top working area that can cut temperature to negative 35 degrees Celsius. Equipped with automatic 24 hour defroster with interrupt key and handwheel brake.Provides protection for knife and specimen as it retracts specimen at the end of the cut. Motorized coarse feed system allows sample to be moved forward and backward.Two knife carriers are available. Standard knife carrier is for knives to be easily clamped in place and adjusted, and the disposable blade holder EC for high- and low-profile blades.
Miligram balance that is used for weighing, tarring, percent weighing, and dynamic weighing for unstable samples. Has maximum capacity of 310 grams. Lab balance utilizes mono block weighing technology with permanent shock protection and built in overload protection as well as automatic calibration.
cxxcbxcbvxcvb
Online TV Channel
Bench top multispectral imaging flow cytometer designed for the acquisition of up to 12 channels of cellular imagery. It combines per cell information with statistical significance of sample sizes of standard flow cytometry.
Invitrogen benchtop automated cell counter. Can perform cell counts, viability calculations, hemocytometry, fluorescent protein expression, and measure fluorescence capabilities. There are also reusable slides, fluorescence capabilities, and brightfield fluorescence channels.