Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
CGB offers range of genomic services, including high-throughput DNA/RNA extraction, library preparation, next-generation sequencing, and bioinformatic analysis.
Proper citation: Indiana University Center for Genomics and Bioinformatics Core Facility (RRID:SCR_017165) Copy
Center that imports, archives, maintains, and distributes mutant mouse alleles as live mice, frozen germplasm, stem cells, and molecular vectors for use in biomedical research. The MMRRC Davis receives transgenics, knockouts, and other kinds of mutant mouse lines at no cost to the donor, and after re-derivation and cryopreservation, distributes breeding stock, germplasm, cells, or tissues of genetically-defined and pathogen-free mice for a small fee to requesting investigators.
Proper citation: University of California at Davis Mutant Mouse Resource and Research Center (RRID:SCR_016448) Copy
https://atagousa.corecommerce.com/PAL-10S-p358.html
Digital hand held pocket refractometer that measures urine specific gravity. It has measurement temperature of 10 to 35 C and sample volume of 0.3ml.
Proper citation: Atago: PAL-10S Pocket Refractometer (RRID:SCR_018439) Copy
https://www.sutter.com/manuals/P-2000_OpMan.pdf
Microprocessor controlled, CO2 laser based micropipette puller.Default configuration allows fabrication of micropipettes for intracellular recording, patch clamping, microinjection and microperfusion.Can store up to 100 separate programs, each consisting of up to 8 command lines. The five parameters set in each command line allow exquisite control of the micropipette taper geometry. Allows the use of wide range of glass diameters from 0.125 to 1.2 mm.
Proper citation: Sutter: P-2000 Laser Micropipette Puller (RRID:SCR_018640) Copy
http://tools.thermofisher.com/content/sfs/manuals/cms_040970.pdf
Automated PCR instrument for automated amplification of nucleic acids with Polymerase Chain Reaction. It has reaction volumes of up to 50 uL and sample temperature range of 4 to 99.9 C.
Proper citation: Thermo Fisher: Applied Biosystems: GeneAmp 9700 PCR Thermocycler System (RRID:SCR_018436) Copy
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on November 14,2023.Automated preparation system that isolates and prepares single cell templates for analysis. It can analyze mRNA and DNA sequencing, epigenetics or miRNA expression. It can extract, reverse transcribe, amplify, and analyze gene expression.
Proper citation: Fluidigm: C1 Single-Cell Automated Preparation System (RRID:SCR_018578) Copy
https://www.marshallscientific.com/Fisher-Scientific-PowerGen-125-Homogenizer-p/fs-pg125.htm
Homogenizer with speeds from 8,000 to 30,000 RPM for volumes of up to 100ml. Homogenizer for production of dispersions and emulsions, plant tissues, human tissues, animal tissues, resins, and pigments.
Proper citation: Thermo Fisher: n125 Homogenizer (RRID:SCR_018576) Copy
https://www.gilson.com/verity-271-hplc-system.html
HPLC liquid handler with midsize bed capacity and fraction collector. It has maximum flow rates up to 200 mL per min, injection loop volumes of 2 uL to 25 mL, and max sample mass of 15 grams per injection.
Proper citation: Gilson: GX-271 HPLC System (RRID:SCR_018579) Copy
EImaging scanner that images fluorescent and radioisotopic samples. It can be used for protein electrophoresis, genomics array analysis, fluorescence, radioisotope detection, and chemiluminescence detection by direct detection method.
Proper citation: Fujifilm: FLA-5100 Scanner (RRID:SCR_018581) Copy
https://www.agilent.com/cs/library/brochures/5990-5596EN.pdf
Agilent 3100 OFFGEL Fractionator performs isoelectric focusing of proteins or peptides in immobilized pH gradient (IPG) gel strips.
Proper citation: Agilent: 3100 OFFGEL Fractionator (RRID:SCR_018433) Copy
https://mobile.labwrench.com/equipment/8044/applied-biosystems/voyager-de-pro
Benchtop MALDI TOF mass spectrometer that has linear and reflector analyzer. It is used to analyze organic and inorganic compounds, protein identification, synthetic peptide validation, and polymer analysis.
Proper citation: Thermo Fisher: Applied Biosystems: ABI Voyager DE Pro MALDI-Mass Spectrometer (RRID:SCR_018432) Copy
https://www.thelabworldgroup.com/mettler-toledo-pb303-precision-balance
Miligram balance that is used for weighing, tarring, percent weighing, and dynamic weighing for unstable samples. Has maximum capacity of 310 grams. Lab balance utilizes mono block weighing technology with permanent shock protection and built in overload protection as well as automatic calibration.
Proper citation: Mettler: PB303-S Milligram Balance (RRID:SCR_018592) Copy
https://www.gmi-inc.com/product/packard-cobra-gamma-counter-series/
Gamma counter available in single, five, or ten detector configurations. Can count RIA tubes, 16x100mm and variety of smaller micro tubes using available adapter.This instrument has dot Matrix Printer, tube racks, and protocol ID tags.Single detector model is available in 2 inch or 3 inch crystal configurations for research grade capabilities.
Proper citation: Packard: Cobra 5000 Gamma Counter (RRID:SCR_018609) Copy
Dual channel fluorimeter for fluorescence measurements when calibrated with known concentration to measure compounds at low concentration with low assay volume.
Proper citation: Promega: TBS-380 Fluorimeter (RRID:SCR_018615) Copy
Microplate luminometer that features two optional injectors and reads both glow- and flash-luminescent reactions in 96-well plates. The sensitivity and range enable a wide range of luminescent assays, including Promega bioluminescent reporter, cell-based and biochemical assays., THIS RESOURCE IS NO LONGER IN SERVICE. Documented on September 16,2025.
Proper citation: Promega: GloMax 96 Microplate Luminometer (RRID:SCR_018614) Copy
Sequencing and quantification platform for epigenetics, mutation gene expression analysis, and microbial identification and resistance typing. With its 96-well format, automatic base-calling function, and dedicated software solutions for methylation analysis and assay design.
Proper citation: Qiagen: PyroMark Q96 System (RRID:SCR_018617) Copy
http://tools.thermofisher.com/content/sfs/brochures/geneatlas_system_brochure.pdf
System for processing Affymetrix microarrays. Microarray analysis system. Includes array strip and hybridization assembly, Fluidics station, Imaging station.
Proper citation: Thermo Fisher: GeneAtlas System (RRID:SCR_018715) Copy
https://www.thermofisher.com/order/catalog/product/ND-8000-GL
Microvolume UV Vis spectrophotometer for nucleic acid and protein quantification that can measure multiple samples using 1 to 2 uL of samples. Can analyze spectrum of 220nm to 750nm and measure 96 samples in less than six minutes. Can measure multiple samples in one measurement cycle, up to eight samples at one time. Has single sample mode. Can analyze the full spectrum from 220 to 750nm and calculates sample purity ratios 260/280.
Proper citation: Thermo Fisher: NanoDrop 8000 Spectrophotometer (RRID:SCR_018600) Copy
https://www.nikonmetrology.com/en-us/product/az100-multizoom
Nikon Instruments AZ100 C1si is macro confocal microscope system combining stereo and compound microscopes into single hybrid imaging system for dynamic imaging of single cells or whole specimens.System covers range of magnifications from 5x to 400x. Has triple nosepiece that can switch magnifications. AZ100 C1si boasts simultaneous 32 channel spectral image acquisition over spectral range of 320 nm in single scan. Simultaneous 32 channel acquisition at 10 nm, 5 nm or 2.5 nm bandwidths, all software controlled, is possible.
Proper citation: Nikon: AZ100 Confocal Microscope (RRID:SCR_018603) Copy
https://www.marshallscientific.com/The-MJ-Research-PTC-100-Thermal-Cycler-p/mj-100.htm
Thermocycler that operates with 96 well and 60 well microplates. Has temperature configurations from 0 C to 105 C and pressure and height adjustment via thumbwheel. Comes with 14 pre-programmed protocols.
Proper citation: Marshall Scientific: MJ Research PTC-100 PCR Thermocycler (RRID:SCR_018602) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the ASWG Resources search. From here you can search through a compilation of resources used by ASWG and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that ASWG has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on ASWG then you can log in from here to get additional features in ASWG such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into ASWG you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within ASWG that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.