Impedance, or oscillometry, measurements of the respiratory system can generate information about the function of the respiratory system not possible with traditional spirometry. There are currently several instruments on the market using different perturbations. We have compared a new respiratory oscillometry instrument, the tremoflo, with Impulse Oscillometry (IOS). Patients with a physician's diagnosis of chronic obstructive lung disease (COPD) and healthy subjects were recruited. They underwent assessment of respiratory function with oscillometry using the IOS and tremoflo devices and the resulting impedance data from the two methods were compared. The two devices were also tested against a reference respiratory phantom with variable resistances. Whereas both devices detected impairments in the patients' lung function commensurate with small airways pathology, the tremoflo appeared to be more sensitive than the IOS. We found systematic differences between the two instruments especially for reactance measurements where the area over the reactance curve (AX) was significantly lower with the IOS compared with the tremoflo (p < 0.001). Moreover, the agreement between the two devices was reduced with increasing severity of the disease as determined with a Bland-Altman test. Testing both instruments against a respiratory phantom unit confirmed that the resistance measured by the tremoflo compares closely with the known resistance of test loads, whereas the IOS' resistance correlated with a test load of 0.19, kPa.s.L-1 at higher loads it deviated significantly from the known resistance (p < 0.0028). We conclude that the absolute values measured with the two devices may not be directly comparable and suggest that differences in the calibration procedures might account for the differences.
Scoliosis is a condition that affects the spine and causes chest rotation and trunk distortion. Individuals with severe deformities may experience dyspnea on exertion and develop respiratory failure. Respiratory oscillometry is a simple and non-invasive method that provides detailed information on lung mechanics. This work aims to investigate the potential of oscillometry in the evaluation of respiratory mechanics in patients with scoliosis and its association with physical performance. We analyzed 32 volunteers in the control group and 32 in the scoliosis group. The volunteers underwent traditional pulmonary function tests, oscillometry, and the 6-minute walk test (6MWT). Oscillometric analysis showed increased values of resistance at 4 Hz (R4, P<0.01), 12 Hz (R12, P<0.0001), and 20 Hz (R20, P<0.01). Similar analysis showed reductions in dynamic compliance (Cdyn, P<0.001) and ventilation homogeneity, as evaluated by resonance frequency (fr, P<0.001) and reactance area (Ax, P<0.001). Respiratory work, described by the impedance modulus, also showed increased values (Z4, P<0.01). Functional capacity was reduced in the group with scoliosis (P<0.001). A significant direct correlation was found between Cobb angle and R12, AX, and Z4 (P=0.0237, P=0.0338, and P=0.0147, respectively), and an inverse correlation was found between Cdyn and Cobb angle (P=0.0190). These results provided new information on respiratory mechanics in scoliosis and are consistent with the involved pathophysiology, suggesting that oscillometry may improve lung function tests for patients with scoliosis.
The World Trade Center (WTC) destruction released dust and fumes into the environment. Although many community members developed respiratory symptoms, screening spirometry was usually normal. We hypothesised that forced oscillation testing would identify functional abnormalities undetected by spirometry and that symptom severity would relate to magnitude of abnormalities measured by oscillometry. A symptomatic cohort (n=848) from the Bellevue Hospital WTC Environmental Health Center was evaluated and compared to an asymptomatic cohort (n=475) from the New York City Department of Health WTC Health Registry. Spirometry and oscillometry were performed. Oscillometry measurements included resistance (R5) and frequency dependence of resistance (R5-20). Spirometry was normal for the majority of subjects (73.2% symptomatic versus 87.6% asymptomatic, p<0.0001). In subjects with normal spirometry, R5 and R5-20 were higher in symptomatic versus asymptomatic subjects (median (interquartile range) R5 0.436 (0.206) versus 0.314 (0.129) kPa·L-1·s-1, p<0.001; R5-20 0.075 (0.085) versus 0.004 (0.042) kPa·L-1·s-1, p<0.0001). In symptomatic subjects, R5 and R5-20 increased with increasing severity and frequency of wheeze (p<0.05). Measurement of R5-20 correlated with the presence and severity of symptoms even when spirometry was within normal limits. These findings are in accord with small airway abnormalities as a potential explanation of the respiratory symptoms.
With several commercially available devices measuring respiratory impedance by oscillometry, the agreement between values obtained on different instruments or frequencies remains unclear. Our aim was to examine the agreement between resistance and reactance parameters on two oscillometry instruments using different waveforms.
Airway oscillometry has become the de facto standard for quality assessment of lung physiology in laboratory animals and has demonstrated its usefulness in understanding diseases of small airways. Nowadays, it is seeing extensive use in daily clinical practice and research; however, a question that remains unanswered is how well physiological findings in animals and humans correlate? Methodological and device differences are obvious between animal and human studies. However, all devices deliver an oscillated airflow test signal and output respiratory impedance. In addition, despite analysis differences, there are ways to interpret animal and human oscillometry data to allow suitable comparisons. The potential with oscillometry is its ability to reveal universal features of the respiratory system across species, making translational extrapolation likely to be predictive. This means that oscillometry can thus help determine if an animal model displays the same physiological characteristics as the human disease. Perhaps more importantly, it can also be useful to determine whether an intervention is effective as well as to understand if it affects the desired region of the respiratory system, e.g., the periphery of the lung. Finally, findings in humans can also inform preclinical scientists and give indications as to what type of physiological changes should be observed in animal models to make them relevant as models of human disease. The present article will attempt to demonstrate the potential of oscillometry in respiratory research, an area where the development of novel therapies is plagued with a failure rate higher than in other disease areas.
Body plethysmography (BP) is the standard pulmonary function test (PFT) in pulmonary emphysema diagnosis, but not all patients can cooperate to this procedure. An alternative PFT, impulse oscillometry (IOS), has not been investigated in emphysema diagnosis. We investigated the diagnostic accuracy of IOS in the diagnosis of emphysema. Eighty-eight patients from the pulmonary outpatient clinic at Lillebaelt Hospital, Vejle, Denmark, were included in this cross-sectional study. A BP and an IOS were performed in all patients. Computed tomography scan verified presence of emphysema in 20 patients. The diagnostic accuracy of BP and IOS for emphysema was evaluated with two multivariable logistic regression models: Model 1 (BP variables) and Model 2 (IOS variables). Model 1 had a cross-validated area under the ROC curve (CV-AUC) = 0.892 (95% CI: 0.654-0.943), a positive predictive value (PPV) = 59.3%, and a negative predictive value (NPV) = 95.0%. Model 2 had a CV-AUC = 0.839 (95% CI: 0.688-0.931), a PPV = 55.2%, and an NPV = 93.7%. We found no statistically significant difference between the AUC of the two models. IOS is quick and easy to perform, and it can be used as a reliable rule-out method for emphysema.
Impulse oscillometry (IOS) allows an effort-independent evaluation of small airway function in asthma. Unfortunately, well-determined minimal clinically important differences (MCIDs) for IOS measures are lacking. Here, we provide MCIDs for frequently used IOS measures, namely frequency dependence of resistance (FDR) and area of reactance (AX), in patients with asthma.
This review describes issues for the estimation of pulse wave velocity (PWV) under ambulatory conditions using oscillometric systems. The difference between the principles of measuring the PWV by the standard method and by oscillometry is shown, and information on device validation studies is summarized. It was concluded that currently oscillometry is a method that is very convenient to use in the 24-hour monitoring of the PWV, is relatively accurate, and is reasonably comfortable for the patient. Several indices with the same principles as those in the analysis of blood pressure in ambulatory monitoring of blood pressure, namely the assessment of load, variability, and circadian rhythm, are proposed.
The pathophysiologic differences between methacholine-induced cough but normal airway sensitivity (COUGH) and healthy individuals (CONTROL) are incompletely understood and may be due to differences in the bronchodilating effect of deep inspirations (DIs). The purpose of this study is to compare the bronchodilating effect of DIs in individuals with classic asthma (CA), cough variant asthma (CVA), and COUGH with CONTROL and to assess impulse oscillometry (IOS) measures as predictors of the bronchodilating effect of DIs.
Lung function analysis in Parkinson's disease (PD) is often difficult due to the demand for adequate forced expiratory maneuvers. Respiratory oscillometry exams require onlyquiet tidal breathing and provide a detailed analysis of respiratory mechanics. We hypothesized that oscillometry would simplify the diagnosis of respiratory abnormalitiesin PD and improve our knowledge about the pathophysiological changes in these patients.
Eosinophil depletion with benralizumab reduces exacerbations and improves disease control and FEV1 in patients with severe eosinophilic asthma. However, few studies have investigated the effect of biologics on small airways dysfunction (SAD) even though the latter correlates better with poor asthma control and type 2 inflammation.
Respiratory oscillometry is gaining global attention over traditional pulmonary function tests for its sensitivity in detecting small airway obstructions. However, its use in clinical settings as a diagnostic tool is limited because oscillometry lacks globally accepted reference values. In this scoping review, we systematically assessed the differences between selected oscillometric reference equations with the hypothesis that significant heterogeneity existed between them. We searched bibliographic databases, registries and references for studies that developed equations for healthy adult populations according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A widely used Caucasian model was used as the standard reference and compared against other models using Bland-Altman and Lin's concordance correlational analyses. We screened 1202 titles and abstracts, and after a full-text review of 67 studies, we included 10 in our analyses. Of these, three models had a low-to-moderate agreement with the reference model, particularly those developed from non-Caucasian populations. Although the other six models had a moderate-to-high agreement with the standard model, there were still significant sex-specific variations. This is the first systematic analysis of the heterogeneity between oscillometric reference models and warrants the validation of appropriate equations in clinical applications of oscillometry to avoid diagnostic errors.
Respiratory oscillometry is widely explored in asthma management; however, there is currently no consensus on its routine work-up in patients with difficult-to-treat asthma. We conducted a retrospective, cross-sectional study involving patients with difficult-to-treat asthma at Asia University Hospital between January 2017 and October 2020. We aimed to correlate clinical significance of respiratory oscillometry and asthma treatment outcomes including symptoms control and exacerbation in patients with difficult-to-treat asthma. Among the 69 patients enrolled in the study, a total of 26.1% of the patients experienced at least one severe or two moderate exacerbations. Patients with ACT < 20 presented a higher prevalence of higher frequency-dependent resistance (FDR; the difference in resistance at 5 Hz and 20 Hz) and frequency of resonance (Fres) than those with ACT ≥ 20. In the multivariable analysis, comorbidities, COPD or allergic rhinitis, and FDR were independent factors in increasing the odds ratio in poorly controlled asthma. (FDR ≥ 0.10 vs. < 0.10, adjusted ORR = 5.05, P = 0.037) There was a higher proportion of frequent exacerbations in patients with higher FDR (FDR ≥ 0.10 vs. < 0.10 = 30.0%:20.7%), but IOS parameters failed to predict frequent exacerbations on further analysis. FDR may be a potential clinical parameter for predicting symptom control in patients with difficult-to-treat asthma.
Bronchial asthma (BA) has different phenotypes, and it requires a clinically effective subtype classification system. The impulse oscillometry system (IOS) is an emerging technique device used in respiratory functional tests. However, its efficacy has not been validated. Therefore, this study aimed to assess the relationship between BA and the IOS parameters, and the difference in the therapeutic effects of inhaled corticosteroids (ICSs) among the subtype classifications was evaluated using the IOS.
Published reference equations for impulse oscillometry (IOS) usually encompass a specific age group but not the entire lifespan. This may lead to discordant predicted values when two or more non-coincident equations can be applied to the same person, or when a person moves from one equation to the next non-convergent equation as he or she gets older. Thus, our aim was to provide a single reference equation for each IOS variable that could be applied from infancy to old age.
The forced oscillation (FOT) and multiple breath washout (MBW) techniques are passive tests of lung function, and are reliable for preschool-age children. There has not been comparison testing to determine which test could more accurately differentiate between healthy controls and poorly controlled asthmatics, or differentiate a response to bronchodilator administration.
Welcome to the FDI Lab - SciCrunch.org Resources search. From here you can search through a compilation of resources used by FDI Lab - SciCrunch.org and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that FDI Lab - SciCrunch.org has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on FDI Lab - SciCrunch.org then you can log in from here to get additional features in FDI Lab - SciCrunch.org such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into FDI Lab - SciCrunch.org you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the facets that you can filter your papers by.
From here we'll present any options for the literature, such as exporting your current results.
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.
Year:
Count: