Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

This service exclusively searches for literature that cites resources. Please be aware that the total number of searchable documents is limited to those containing RRIDs and does not include all open-access literature.

Search

Type in a keyword to search

On page 1 showing 1 ~ 20 papers out of 866 papers

Indication-specific 6-h systolic blood pressure thresholds can approximate 24-h determination of blood pressure control.

  • M E Ernst‎ et al.
  • Journal of human hypertension‎
  • 2011‎

Ambulatory blood pressure monitoring (ABPM) is an accurate method for evaluating hypertension, yet its use in clinical practice may be limited by availability, cost and patient inconvenience. The objective of this study was to investigate the ability of a 6-h ABPM window to predict blood pressure control, judging by that of the full 24-h ABPM session across several clinical indications in a cohort of 486 patients referred for ABPM. Sensitivities and specificities of the 6-h systolic blood pressure mean to accurately classify patients as hypertensive were determined using a fixed reference point of 130 mm Hg for the 24-h mean. For four common indications, in which ABPM was ordered, prediction tables were constructed varying the thresholds for the 6-h mean to find the optimal value that best predicted the 24-h hypertensive status as determined from the full 24-h interval. Using a threshold of 137 mm Hg for the indications of borderline hypertension, evaluation of current antihypertensive regimen and suspected white-coat hypertension, sensitivity and specificity ranged from 0.83-0.88 to 0.80-0.88, respectively, for the ability of 6-h ABPM to correctly categorize hypertensive status. Using 133 mm Hg as the threshold for treatment resistance resulted in a sensitivity and specificity of 0.93 and 0.83, respectively. We conclude that a shortened ABPM session of 6 h can be used to accurately classify blood pressure as controlled or not, based on the results of a 24-h session. The optimal 6-h threshold for comparison depends upon indication for referral.


Automatic determination of penile blood pressure in evaluation of vasculogenic impotence.

  • G C Vignoli‎
  • Urology‎
  • 1982‎

No abstract available


Determination of the psychometric properties of the Patients' Self-Efficacy Scale in blood pressure patients.

  • Raheleh Ghadiri‎ et al.
  • Interventional medicine & applied science‎
  • 2018‎

This study was designed to determine self-efficacy and its related factors in patients with hypertension.


Genome-wide scan identifies CDH13 as a novel susceptibility locus contributing to blood pressure determination in two European populations.

  • Elin Org‎ et al.
  • Human molecular genetics‎
  • 2009‎

Hypertension is a complex disease that affects a large proportion of adult population. Although approximately half of the inter-individual variance in blood pressure (BP) level is heritable, identification of genes responsible for its regulation has remained challenging. Genome-wide association study (GWAS) is a novel approach to search for genetic variants contributing to complex diseases. We conducted GWAS for three BP traits [systolic and diastolic blood pressure (SBP and DBP); hypertension (HYP)] in the Kooperative Gesundheitsforschung in der Region Augsburg (KORA) S3 cohort (n = 1644) recruited from general population in Southern Germany. GWAS with 395,912 single nucleotide polymorphisms (SNPs) identified an association between BP traits and a common variant rs11646213 (T/A) upstream of the CDH13 gene at 16q23.3. The initial associations with HYP and DBP were confirmed in two other European population-based cohorts: KORA S4 (Germans) and HYPEST (Estonians). The associations between rs11646213 and three BP traits were replicated in combined analyses (dominant model: DBP, P = 5.55 x 10(-5), effect -1.40 mmHg; SBP, P = 0.007, effect -1.56 mmHg; HYP, P = 5.30 x 10(-8), OR = 0.67). Carriers of the minor allele A had a decreased risk of hypertension. A non-significant trend for association was also detected with severe family based hypertension in the BRIGHT sample (British). The novel susceptibility locus, CDH13, encodes for an adhesion glycoprotein T-cadherin, a regulator of vascular wall remodeling and angiogenesis. Its function is compatible with the BP biology and may improve the understanding of the pathogenesis of hypertension.


Does home blood pressure monitoring improve patient outcomes? A systematic review comparing home and ambulatory blood pressure monitoring on blood pressure control and patient outcomes.

  • Tonya L Breaux-Shropshire‎ et al.
  • Integrated blood pressure control‎
  • 2015‎

Our objective was to compare the clinical effectiveness of home blood pressure monitoring (HBPM) and 24-hour ambulatory blood pressure monitoring (ABPM) on blood pressure (BP) control and patient outcomes.


Brain-based arterial pulse pressure threshold for death determination: a systematic review.

  • Saptharishi Lalgudi Ganesan‎ et al.
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie‎
  • 2023‎

There is lack of consensus regarding the minimum arterial pulse pressure required for confirming permanent cessation of circulation for death determination by circulatory criteria in organ donors. We assessed direct and indirect evidence supporting whether one should use an arterial pulse pressure of 0 mm Hg vs more than 0 (5, 10, 20, 40) mm Hg to confirm permanent cessation of circulation.


Determination of health workers' level of knowledge about blood transfusion.

  • Aysegul Beyazpinar Kavaklioglu‎ et al.
  • Northern clinics of Istanbul‎
  • 2017‎

This study was conducted to determine the knowledge level of healthcare workers about blood transfusion.


Transfer-function-free technique for the noninvasive determination of the human arterial pressure waveform.

  • Alessandro Giudici‎ et al.
  • Physiological reports‎
  • 2021‎

The estimation of central aortic blood pressure is a cardinal measurement, carrying effective physiological, and prognostic data beyond routine peripheral blood pressure. Transfer function-based devices effectively estimate aortic systolic and diastolic blood pressure from peripheral pressure waveforms, but the reconstructed pressure waveform seems to preserve features of the peripheral waveform. We sought to develop a new method for converting the local diameter distension waveform into a pressure waveform, through an exponential function whose parameters depend on the local wave speed. The proposed method was then tested at the common carotid artery. Diameter and blood velocity waveforms were acquired via ultrasound at the right common carotid artery while simultaneously recording pressure at the left common carotid artery via tonometer in 203 people (122 men, 50 ± 18 years). The wave speed was noninvasively estimated via the lnDU-loop method and then used to define the exponential function to convert the diameter into pressure. Noninvasive systolic and mean pressures estimated by the new technique were 3.8 ± 21.8 (p = 0.015) and 2.3 ± 9.6 mmHg (p = 0.011) higher than those obtained using tonometery. However, differences were much reduced and not significant in people >35 years (0.6 ± 18.7 and 0.8 ± 8.3 mmHg, respectively). This proof of concept study demonstrated that local wave speed, estimated from noninvasive local measurement of diameter and flow velocity, can be used to determine an exponential function that describes the relationship between local pressure and diameter. This pressure-diameter function can then be used for the noninvasive estimation of local arterial pressure.


Determination of ABO blood grouping and Rhesus factor from tooth material.

  • Pooja Vijay Kumar‎ et al.
  • Journal of oral and maxillofacial pathology : JOMFP‎
  • 2016‎

The aim of the study was to determine blood groups and Rhesus factor from dentin and pulp using absorption-elution (AE) technique in different time periods at 0, 3, 6, 9 and 12 months, respectively.


Blood Pressure Patterns in Patients with Parkinson's Disease: A Systematic Review.

  • Delia Tulbă‎ et al.
  • Journal of personalized medicine‎
  • 2021‎

(1) Background: Cardiovascular autonomic dysfunction is a non-motor feature in Parkinson's disease with negative impact on functionality and life expectancy, prompting early detection and proper management. We aimed to describe the blood pressure patterns reported in patients with Parkinson's disease, as measured by 24-h ambulatory blood pressure monitoring. (2) Methods: We conducted a systematic search on the PubMed database. Studies enrolling patients with Parkinson's disease undergoing 24-h ambulatory blood pressure monitoring were included. Data regarding study population, Parkinson's disease course, vasoactive drugs, blood pressure profiles, and measurements were recorded. (3) Results: The search identified 172 studies. Forty studies eventually fulfilled the inclusion criteria, with 3090 patients enrolled. Abnormal blood pressure profiles were commonly encountered: high blood pressure in 38.13% of patients (938/2460), orthostatic hypotension in 38.68% (941/2433), supine hypertension in 27.76% (445/1603) and nocturnal hypertension in 38.91% (737/1894). Dipping status was also altered often, 40.46% of patients (477/1179) being reverse dippers and 35.67% (310/869) reduced dippers. All these patterns were correlated with negative clinical and imaging outcomes. (4) Conclusion: Patients with Parkinson's disease have significantly altered blood pressure patterns that carry a negative prognosis. Ambulatory blood pressure monitoring should be validated as a biomarker of PD-associated cardiovascular dysautonomia and a tool for assisting therapeutic interventions.


Continuous Blood Pressure Estimation From Electrocardiogram and Photoplethysmogram During Arrhythmias.

  • ZengDing Liu‎ et al.
  • Frontiers in physiology‎
  • 2020‎

Continuous blood pressure (BP) provides valuable information for the disease management of patients with arrhythmias. The traditional intra-arterial method is too invasive for routine healthcare settings, whereas cuff-based devices are inferior in reliability and comfortable for long-term BP monitoring during arrhythmias. The study aimed to investigate an indirect method for continuous and cuff-less BP estimation based on electrocardiogram (ECG) and photoplethysmogram (PPG) signals during arrhythmias and to test its reliability for the determination of BP using invasive BP (IBP) as reference.


Subclinical Posttraumatic Stress Disorder Symptoms: Relationships with Blood Pressure, Hostility, and Sleep.

  • James A McCubbin‎ et al.
  • Cardiovascular psychiatry and neurology‎
  • 2016‎

The purpose of this study was to examine the relationships among subclinical PTSD symptoms, blood pressure, and several variables linked to both frank PTSD and the basic psychobiological adaptation to stress. The authors recruited a sample of 91 healthy, young men and women between 18 and 35 years. We examined links among subclinical posttraumatic stress disorder symptoms, blood pressure, sleep quality, and hostility. Posttraumatic stress disorder symptoms were associated with poorer sleep quality and higher hostility scores in both women and men. In men, PTSD symptoms were also associated with elevated resting diastolic blood pressure, and sex was an important moderator of that relationship. Moreover, sleep quality and hostility are substantive mediators of the relationship between diastolic blood pressure and PTSD. Behavioral interventions designed to increase sleep quality and restructure hostile attitudes could potentially serve as preventive interventions for PTSD and the underlying cardiovascular comorbidities in young adults.


Genetic variation in salt taste receptors impact salt intake and blood pressure.

  • Noushin Mohammadifard‎ et al.
  • Scientific reports‎
  • 2023‎

So far, few studies have examined the effect of salt taste receptors genetic variation on dietary intake in the Iranian population. We aimed to evaluate associations between single nucleotide polymorphisms (SNPs) in salt taste receptors' genes with dietary salt intake and blood pressure. A cross-sectional study was carried out among 116 randomly selected healthy adults aged ≥ 18 in Isfahan, Iran. Participants underwent sodium intake determination by 24-h urine collection, as well as dietary assessment by semi-quantitative food frequency questionnaire and blood pressure measurement. Whole blood was collected to extract DNA and genotype of SNP rs239345 in SCNN1B and rs224534, rs4790151 and rs8065080 in TRPV1 gene. Sodium consumption and diastolic blood pressure were significantly higher in carriers of the A-allele in rs239345 compared to subjects with the TT genotype (4808.4 ± 824.4 mg/day vs. 4043.5 ± 989.3 mg/day; P = 0.004) and 83.6 ± 8.5 mmHg vs. 77.3 ± 7.3 mmHg; P = 0.011), respectively. The level of sodium intake was lower in the TT genotype of TRPV1 (rs224534) than the CC genotype (3767.0 ± 713.7 mg/day vs. 4633.3 ± 793.5 mg/day; P = 0.012). We could not find any association between genotypes of all SNPs with systolic blood pressure as well as genotypes of rs224534, rs4790151 and rs8065080 with diastolic blood pressure. Genetic variations can relate with salt intake and consequently may associate with hypertension and finally cardiovascular disease risk in the Iranian population.


Water as a Blood Model for Determination of CO2 Removal Performance of Membrane Oxygenators.

  • Benjamin Lukitsch‎ et al.
  • Membranes‎
  • 2021‎

CO2 removal via membrane oxygenators has become an important and reliable clinical technique. Nevertheless, oxygenators must be further optimized to increase CO2 removal performance and to reduce severe side effects. Here, in vitro tests with water can significantly reduce costs and effort during development. However, they must be able to reasonably represent the CO2 removal performance observed with blood. In this study, the deviation between the CO2 removal rate determined in vivo with porcine blood from that determined in vitro with water is quantified. The magnitude of this deviation (approx. 10%) is consistent with results reported in the literature. To better understand the remaining difference in CO2 removal rate and in order to assess the application limits of in vitro water tests, CFD simulations were conducted. They allow to quantify and investigate the influences of the differing fluid properties of blood and water on the CO2 removal rate. The CFD results indicate that the main CO2 transport resistance, the diffusional boundary layer, behaves generally differently in blood and water. Hence, studies of the CO2 boundary layer should be preferably conducted with blood. In contrast, water tests can be considered suitable for reliable determination of the total CO2 removal performance of oxygenators.


Blood mercury level and blood pressure among US women: results from the National Health and Nutrition Examination Survey 1999-2000.

  • Suma Vupputuri‎ et al.
  • Environmental research‎
  • 2005‎

Exposure to mercury has been linked to elevations in blood pressure (BP), though few data are available. We examined the cross-sectional relationship between blood mercury concentration and BP in a representative US sample of 1240 women, aged 16-49 years, from the National Health and Nutrition Examination Survey 1999-2000. We found no association overall between mercury and BP in multivariate models. We stratified our data by dietary fish intake (presumably reflecting the consumption of long-chain n-3 fatty acids that may reduce BP) resulting in 759 fish consumers and 481 non-fish consumers. We found that for each 1.3 microg/L (interquartile distance) increase in mercury, systolic BP significantly increased by 1.83 mm Hg (95% CI: 0.36, 3.30) among non-fish consumers. A similar pattern was seen for diastolic BP, although it was non-significant. While an adverse effect of mercury exposure at background levels on BP was not present overall, an adverse association was present among non-fish-consuming young and middle-aged women.


Extraction of 3,4,4'-Trichlorocarbanilide from Rat Fecal Samples for Determination by High Pressure Liquid Chromatography-Tandem Mass Spectrometry.

  • Rebekah C Kennedy‎ et al.
  • International journal of environmental research and public health‎
  • 2015‎

Triclocarban (3,4,4'-Trichlorocarbanilide; TCC) in the environment has been well documented. Methods have been developed to monitor TCC levels from various matrices including water, sediment, biosolids, plants, blood and urine; however, no method has been developed to document the concentration of TCC in fecal content after oral exposure in animal studies. In the present study, we developed and validated a method that uses liquid extraction coupled with HPLC-MS/MS determination to measure TCC in feces. The limit of detection and limit of quantitation in control rats without TCC exposure was 69.0 ng/g and 92.9 ng/g of feces, respectively. The base levels of TCC in feces were lower than LOD. At 12 days of treatment, the fecal TCC concentration increased to 2220 µg/g among 0.2% w/w exposed animals. The concentration in fecal samples decreased over the washout period in 0.2% w/w treated animals to 0.399 µ/g feces after exposure was removed for 28 days. This method required a small amount of sample (0.1 g) with simple sample preparation. Given its sensitivity and efficiency, this method may be useful for monitoring TCC exposure in toxicological studies of animals.


The effect of the first office blood pressure reading on hypertension-related clinical decisions.

  • Idris Oladipo‎ et al.
  • Cardiovascular journal of Africa‎
  • 2012‎

The effect of the first office blood pressure reading (FBPR) on hypertension-related decisions was evaluated using blood pressure (BP) readings taken with the BpTRU BPM-100 device. BP readings were grouped into three pairs: (1) single readings (first and second readings), (2) computed average of three readings (one including and one excluding the first reading), and (3) computed average of five readings (one including and one excluding the first reading). Categorisation of BP readings under JNC-7 classes and distribution into < 140/90 and ≥ 140/90 mmHg groups were selected as parameters guiding hypertension-related decisions. Readings including FBPR had strong positive correlations to those excluding FBPR (Pearson's correlation coefficient ranged from 0.86-1.00). Also, FBPR-included and FBPR-excluded readings did not differ statistically in JNC-7 categorisation or distribution into < 140/90 or ≥ 140/90 mmHg groups. Our findings suggest that exclusion of FBPR may have no significant impact on hypertension-related clinical decisions.


Randomized study to compare valsartan +/- HCTZ versus amlodipine +/- HCTZ strategies to maximize blood pressure control.

  • Dion Zappe‎ et al.
  • Vascular health and risk management‎
  • 2009‎

Delays in achieving blood pressure (BP) control may increase morbidity and mortality in patients with hypertension. Thus, deciding which antihypertensive agent to use and at what dosage, in addition to determining when to initiate combination therapy and which agents to combine, is important for achieving BP control.


Pressure Algometry Validation and Determination of Efficacy of Articaine Hydrochloride Ring Block in Antler Removal in Red Deer (Cervus elaphus).

  • Farzin Sahebjam‎ et al.
  • Animals : an open access journal from MDPI‎
  • 2020‎

New Zealand deer farming centres on the production of meat and velvet antler. Velvet antler removal is a painful procedure and currently, New Zealand Animal Welfare regulations dictate surgical removal of velvet antlers under lignocaine anaesthesia. To improve our knowledge on the efficacy and duration of other local anaesthetics to mitigate pain after antler removal, it is important to accurately assess and quantify pain arising from antler removal. Therefore, the current study was designed to validate mechanical nociceptive threshold (MNT) testing using a Wagner hand-held algometer, and to apply this methodology to assess the efficacy and duration of action of articaine for antler removal in deer. Baseline force (N) required to elicit the nociceptive response was recorded in 40 yearling male red deer on three alternate days. Ten of the 40 animals were selected for antler removal after administration of 4% articaine hydrochloride as a ring block. The duration of analgesic efficacy of articaine was assessed by algometry across 5 time points. There was a significant difference in MNTs among the three days (day 3 versus day 1 (p < 0.0001), day 2 versus day 1 (p < 0.0001), and day 1 versus day 2 (p < 0.01)). Positive correlations were observed between weight, antler length and thresholds. The MNT values remained above 20N for 6 h after removal of velvet antlers under the articaine ring block. This study provides valuable information about the use of MNT in red deer. These findings lay a foundation for future studies in the topics of peri-operative and postoperative pain management in deer antler removal, and a possible alternative use for articaine.


Comparison of two portable clinical analyzers to one stationary analyzer for the determination of blood gas partial pressures and blood electrolyte concentrations in horses.

  • Katharina Kirsch‎ et al.
  • PloS one‎
  • 2019‎

Portable blood gas analyzers are used to facilitate diagnosis and treatment of disorders related to disturbances of acid-base and electrolyte balance in the ambulatory care of equine patients. The aim of this study was to determine whether 2 portable analyzers produce results in agreement with a stationary analyzer. Blood samples from 23 horses hospitalized for various medical reasons were included in this prospective study. Blood gas analysis and electrolyte concentrations measured by the portable analyzers VetStat and epoc were compared to those produced by the cobas b 123 analyzer via concordance analysis, Passing-Bablok regression and Bland-Altman analysis. Limits of agreement indicated relevant bias between the VetStat and cobas b 123 for partial pressure of oxygen (pO2; 27.5-33.8 mmHg), sodium ([Na+]; 4.3-21.6 mmol/L) and chloride concentration ([Cl-]; 0.3-7.9 mmol/L) and between the epoc and cobas b 123 for pH (0.070-0.022), partial pressure of carbon dioxide (pCO2; 3.6-7.3 mmHg), pO2 (36.2-32.7 mmHg) and [Na+] (0.38.1 mmol/L). The VetStat analyzer yielded results that were in agreement with the cobas b 123 analyzer for determination of pH, pCO2, bicarbonate ([HCO3-]) and potassium concentration [K+], while the epoc analyzer achieved acceptable agreement for [HCO3-] and [K+]. The VetStat analyzer may be useful in performing blood gas analysis in equine samples but analysis of [Na+], [Cl-] and pO2 should be interpreted with caution. The epoc delivered reliable results for [HCO3-] and [K+], while results for pH, pCO2, pO2 and [Na+] should be interpreted with caution.


  1. SciCrunch.org Resources

    Welcome to the FDI Lab - SciCrunch.org Resources search. From here you can search through a compilation of resources used by FDI Lab - SciCrunch.org and see how data is organized within our community.

  2. Navigation

    You are currently on the Community Resources tab looking through categories and sources that FDI Lab - SciCrunch.org has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.

  3. Logging in and Registering

    If you have an account on FDI Lab - SciCrunch.org then you can log in from here to get additional features in FDI Lab - SciCrunch.org such as Collections, Saved Searches, and managing Resources.

  4. Searching

    Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:

    1. Use quotes around phrases you want to match exactly
    2. You can manually AND and OR terms to change how we search between words
    3. You can add "-" to terms to make sure no results return with that term in them (ex. Cerebellum -CA1)
    4. You can add "+" to terms to require they be in the data
    5. Using autocomplete specifies which branch of our semantics you with to search and can help refine your search
  5. Save Your Search

    You can save any searches you perform for quick access to later from here.

  6. Query Expansion

    We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.

  7. Collections

    If you are logged into FDI Lab - SciCrunch.org you can add data records to your collections to create custom spreadsheets across multiple sources of data.

  8. Facets

    Here are the facets that you can filter your papers by.

  9. Options

    From here we'll present any options for the literature, such as exporting your current results.

  10. Further Questions

    If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.

Publications Per Year

X

Year:

Count: