Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
https://www.eppendorf.com/gb-en/eShop-Products/PCR/Thermocyclers/Mastercycler-nexus-p-PF-14698
Thermal cycler conduct PCR runs with range of standard vessel types, from 0.2 mL tubes to 96 well plates using single 96-well aluminum block. Can accommodate 96-well PCR plates, 0.2 mL PCR tubes, 0.2 mL PCR tube strips, and 0.5 mL PCR tubes.Mastercycler nexus cycler can email you when PCR run is complete.
Proper citation: Eppendorf: Mastercycler nexus PCR Thermal Cycler (RRID:SCR_023266) Copy
https://bioscience.lonza.com/lonza_bs/JP/en/Transfection/p/000000000000276883/4D-Nucleofector-X-Unit
One of four functional modules of 4D-Nucleofector System. It supports Nucleofection of various cell numbers cells in different formats.
Proper citation: Lonza: 4D Nucleofector X Unit (RRID:SCR_023155) Copy
https://www.thermofisher.com/order/catalog/product/50143210?SID=srch-srp-50143210
Storage used for high capacity random access storage (210 SBS microplates) at ambient conditions. The Cytomat 10 Hotel (PH) offers multiple transfer positions, dual access point (DAP) and as combined benchtop-under bench solution, it allows flexible placement within the laboratory.
Proper citation: Thermo Fisher: Cytomat 10 Hotel Ambient Storage (RRID:SCR_023273) Copy
https://www.medicalexpo.com/ja/prod/erma/product-68401-922563.html
Automatic cell counting instrument. Used to count blood cells.
Proper citation: ERMA: Automatic blood cell counter PCE-210N (RRID:SCR_023148) Copy
Eppendorf manual, autoclavable, air-cushion pipette for accurate ergonomic pipetting of aqueous solutions.
Proper citation: Eppendorf: Research plus 100-1000 uL 1 channel pipette (RRID:SCR_023466) Copy
Mechanical and autoclavable, manual, air cushion pipette for accurate, ergonomic pipetting of aqueous solutions.
Proper citation: Eppendorf: Research plus 2 ��� 20 ��L yellow 1 channel pipette (RRID:SCR_023465) Copy
Mechanical and autoclavable, manual, air cushion pipette for accurate, ergonomic pipetting of aqueous solutions.
Proper citation: Eppendorf: Research plus 20 ��� 200 ��L yellow 1 channel pipette (RRID:SCR_023464) Copy
Chromatography system for purification in research applications. Allows for customization due to its modular design with flow rate. Available with flow rate of up to 25 mL/min or flow rate of up to 150 mL/min. Offers more than 20 hardware options for custom system, including new UV monitor.Includes Air sensor L9;CELL 2 U KPL;Conductivity monitor C9n Cpl;Injection valve V9-Inj;Instrument control unit, I9, Äkta pure; Mixer M9;Pressure monitor R9-2 with pump restrictor; Pump P9 Cpl 2x; UV Monitor U9-L Cpl;Fraction collector F9-R, Cytiva, CAT# 29011362;Superdex 200 increase 10/300 GL, Cytiva, CAT# 28-9909-44.
Proper citation: Cytiva: AKTA pure 25 L chromatography system (RRID:SCR_023461) Copy
https://www.nanoentek.com/theme/nanont2_en/shop/02/product01_view.php?it_id=1547538993
Bench top size cell counter that is designed to count cells and verify viability accurately and precisely, using standard trypan blue technique and provides image analysis for cell counting.
Proper citation: NanoEntek: EVE Automated Cell Counter (RRID:SCR_023459) Copy
https://lifesciences.tecan.com/microplate-washers-hydrospeed?p=tab--1
Advanced plate washer, designed for quick, parallel washing of entire 96- and 384-well plates. This avoids time differences between wells for uniform results. Provides full control of wash power for optimized washing of cells, beads and ELISAs. Equipped with 96 and 384 indexing wash head and optimized magnetic carriers.
Proper citation: Tecan: HydroSpeed plate washer (RRID:SCR_023457) Copy
https://www.diagenode.com/en/categories/bioruptor-shearing-device
Sonication system for optimal shearing of biological and chemical samples.
Proper citation: Diagenode: Bioruptor (RRID:SCR_023470) Copy
https://www.gmi-inc.com/product/nuaire-labgard-es-nu-425-biosafety-cabinet-series-2/
Designed for laboratory safety, proper ergonomics, and energy efficiency.Models available from GMI are 2-ft. NU-425-200, 3-ft. NU-425-300, 4-ft. NU-425-400, and 6-ft. NU-425-600. LabGard NU-425 biosafety cabinets feature control system to control blower, lights, and outlets, Minihelic gauge that measures plenum performance, and Attenumount vibration control system for attenuation of sound and vibration. Cabinets are equipped with highly efficient, energy-saving motor/blower to increase filter life and cut electricity costs.
Proper citation: NuAire: LabGard ES NU-425-600E Biosafety Cabinet (RRID:SCR_023448) Copy
Fluorescence activated cell analyzing instrument by BD Biosciences. Allows for the simultaneous detection of up to 30 parameters and 28 colors.
Proper citation: BD Biosciences: FACSymphony A3 Cell Analyzer (RRID:SCR_023644) Copy
Cell imaging system for fast, automated imaging in fixed and live cells. Instrument can rapidly image cells using laser autofocusing, LED light source and CMOS camera.
Proper citation: GE: Healthcare: IN Cell Analyzer 2200 (RRID:SCR_023616) Copy
https://www.illumina.com/systems/sequencing-platforms/nextseq-1000-2000.html
Sequencing system supports range of methods such as exome sequencing, target enrichment, single-cell profiling.
Proper citation: Illumina: NextSeq 2000 system (RRID:SCR_023614) Copy
https://www.ionpath.com/mibiscope/
Imaging platform, enabling phenotypic profiling and spatial analysis of tissue microenvironment. Enables over 40 markers to be visualized simultaneously with single step staining and single step imaging.
Proper citation: Ionpath: MIBIscope System (RRID:SCR_023613) Copy
https://www.htximaging.com/htx-m5-sprayer
Sprayer builds on capabilities of HTX TM-Sprayer providing innovative M5 chassis, high velocity stage and heated sample holder drawer. Sample plate holder is mounted on drawer mechanism to allow easy loading of samples, better protection of user and better alignment of various plate types. New High-Velocity XY stage allows nozzle displacement speed of up to 5,600mm/min and expands process range. Super dry spray can be achieved at high flow rates of solvent further improving instrument performance. E/Z trough gutter design improves chemical containement and is easy to remove and clean. Bulkhead connectors are directly mounted on it to also allow easy access to in line filter.
Proper citation: HTXImaging: M5 Sprayer (RRID:SCR_023733) Copy
https://andor.oxinst.cn/products/scmos-camera-series/zyla-4-2-scmos
Zyla 4.2 PLUS is the latest sCMOS technology advancement from Andor. At its heart, Zyla 4.2 PLUS benefits from latest generation sCMOS sensor technology, delivering a further 10 % boost in QE, resulting in an unprecedented 82% QEmax.
Proper citation: Andor: Zyla 4.2 sCMOS (RRID:SCR_023610) Copy
Mass spectrometer designed for most difficult analytical challenges. Incorporates inventions in ion transmission and control, extended m/z range, and real-time decision making. System suited for proteomics, structural biology, small-molecule, and biopharmaceutical characterization experiments.
Proper citation: Thermo Fisher: Orbitrap Eclipse Tribrid mass spectrometer (RRID:SCR_023618) Copy
Inverted microscope Axio Observer 3 for transmitted light brightfield LED and differential interference contrast. Used for demanding multimodal imaging.
Proper citation: Zeiss: Axio Observer 3 (RRID:SCR_023693) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the nidm-terms Resources search. From here you can search through a compilation of resources used by nidm-terms and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that nidm-terms has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on nidm-terms then you can log in from here to get additional features in nidm-terms such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into nidm-terms you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within nidm-terms that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.