Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
SciCrunch Registry is a curated repository of scientific resources, with a focus on biomedical resources, including tools, databases, and core facilities - visit SciCrunch to register your resource.
https://www.leica-microsystems.com/products/light-microscopes/p/leica-dmi6000-b/
Inverted microscope for biomedical research. Offers Differential Interference Contrast for relief imaging of specimens with varying indices of refraction. Used for fluorescence, live cell, time-lapse imaging, high-speed multi-fluorescence optical sectioning, and micromanipulation. Features automated contrast and illumination manager, motorized Z focus, parfocality function, automatic brightness and diaphragm adjustment, and many other automated functions that provide convenience and reproducible results. Archived Product. Replaced by DMi8 S.
Proper citation: Leica: DMI6000 B inverted microscope (RRID:SCR_018713) Copy
Inverted fluorescence tissue culture microscope capable of imaging specimens in brightfield, darkfield, phase contrast, Hoffman modulation contrast, fluorescence, and differential interference contrast modes.TIRFM-IX illuminator is this microscope accessory which attaches to the rear lamphouse port and contains FC connector for external laser source and port for mercury or xenon lamp housing.
Proper citation: Olympus: IX70 Inverted Fluorescence Microscope (RRID:SCR_018604) Copy
http://tools.thermofisher.com/content/sfs/brochures/PS-64079-MS-TSQ-Quantiva-PS64079-EN.pdf
Triple stage quadrupole mass spectrometer for low level quantitation and has mass range of mass per charge 10 to 1800 mass per charge. Laboratory room temperature must be maintained between 18 to 27 C and cannot change by more than 5 C.
Proper citation: Thermo Fisher: TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer (RRID:SCR_018650) Copy
https://mass-spec.stanford.edu/instruments
Thermo Exactive benchtop Orbitrap operates with Waters Acquity UPLC and generates high resolution, high mass accuracy full MS data. Available to advanced open access users for reversed phase and HILIC LC/MS applications.
Proper citation: Thermo Fisher: Exactive Orbitrap LC/MS system (RRID:SCR_018700) Copy
https://www.blockscientific.com/roche-integra-400-plus#attr=
COBAS INTEGRA 400 plus analyzer is a chemistry analyzer with a broad test menu comprises over 120 assays and applications that consolidate clinical chemistry with specific proteins, therapeutic drug monitoring and drug abuse testing.The Cobas 400 analyzer is best for laboratories running up to 400 samples per day. This compact tabletop analyzer offers maximum versatility to improve efficiency and reduce costs. It uses the convenient cobas c pack reagent format, which standardizes patient results across integrated laboratory networks.
Proper citation: Roche: Cobas Integra 400 Plus Chemistry Analyzer (RRID:SCR_018629) Copy
https://www.marshallscientific.com/Thermo-Shandon-Cytospin-3-Centrifuge-p/th-cyto3.htm
Thermo Shandon Cytospin 3 is low speed centrifuge used to separate and deposit monolayer of cells on slides while maintaining cellular integrity.Centrifuge has speed range between 200 and 2000 RPM, and has holding capacity of up to 24 samples in 12 chambers.
Proper citation: Thermo Fisher: Shandon Cytospin 3 Centrifuge (RRID:SCR_018628) Copy
Hybrid quadrupole time of flight mass spectrometer with MS mass range 6,000 and 40,000 m z designed proteomics, drug discovery, metabolomics, and drug development. Instrument used with Analyst QS software.
Proper citation: SCIEX: QStar XL Mass Spectrometer (RRID:SCR_018627) Copy
https://www.labx.com/item/rigaku-x-stream-2000-cryogenic-crystal-cooler-system/LV40211010
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on March 11,2024. Self contained cryo freezing system designed cooling crystals with range of negative 80C to 4C. It produces nitrogen, which is then cooled to negative 196C, and then rewarmed to desired temperature.
Proper citation: Rigaku: X-Stream 2000 Cryo-Freezing System (RRID:SCR_018633) Copy
https://www.fishersci.com/shop/products/shandon-finesse-325-manual-microtome/p-4529936
Manual microtome with flywheel for routine paraffin sectioning. Can cut 1 to 30 um speciment thickness, and specimen tilt or orientation is plus or minus 5 degrees using X Y micro adjustment.Has quick release cassette clamp and x-y orientation head supplied as standard, disposable blades or standard microtome knives.
Proper citation: Thermo Fisher: Shandon 325 Manual Microtome (RRID:SCR_018632) Copy
Microplate reader that can read one sample or up to 384 in single plate read using any standard cuvette, 12 x 75 mm test tube, or 96 or 384 well microplate. It can run standard spectrophotometer and microplate reader applications.
Proper citation: Molecular Devices: Spectramax Plus384 Microplate Reader (RRID:SCR_018598) Copy
https://www.milabs.com/u-spect/
Nuclear imager for quantitative 3D functional imaging of SPECT tracers down to 0.12 mm ex vivo and 0.25 mm in vivo. Used for quantitative sub mm imaging of higher energy and theranostic isotopes such as 131I, 188Re, 213Bi, 225Ac, and 223Ra.
Proper citation: MILabs: U Spect Nuclear Imager (RRID:SCR_018597) Copy
https://www.sutter.com/manuals/P-97-DOM_OpMan.pdf
Pipette puller that fabricates pipettes for use in intracellular recording, patch clamping, transferring ICSI, ES Cells , microinjection, aspiration, and microperfusion. P-97 puller can indirectly sense viscosity of glass, giving the ability to pull pipettes from all glasses except quartz. Even difficult to pull formulations, such as aluminosilicate glasses, are handled with relative ease.
Proper citation: Sutter: P-97/PC Pipette Puller (RRID:SCR_018636) Copy
Automated cell sorter that has microfluidics sorting chip integrated with six fluorescence detectors and up to four collinear excitation lasers of 488 nm, 405 nm, 561 nm and 638 nm.
Proper citation: Sony biotechnology: SH800Z Cell Sorter (RRID:SCR_018635) Copy
Siemens Dade Behring BN II Nephelometer is leading fully automated system for plasma protein determinations. BN II systems offer advanced nephelometric technology that provides performance in plasma protein analysis. This instrument's menu covers assays, which support various clinical tests including cardiac risk assessment, kidney diseases and nutritional assessment. markers such as Cystatin C and Carbohydrate-Deficient Transferrin (CDT) are also supported. Other features of the Dade Behring BN II Nephelometer include rapid processing, easy operation and random-access mode. The nephelometer also permits users to put up to 100 samples on board, making it best for mid to high-volume processing.
Proper citation: Siemens: Dade Behring BNII Nephelometer System (RRID:SCR_018634) Copy
https://assets.thermofisher.com/TFS-Assets/LED/Specification-Sheets/Hydra_II_Spec_Sheet_FINAL.pdf
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on February 22,2024. Bench top 96 or 384 channel liquid handler capable of automating pipetting tasks, including low volume and viscous sample transfers. It utilizes syringe based technology to dispense solutions.
Proper citation: Thermo Fisher: Hydra II Microdispenser (RRID:SCR_018638) Copy
https://www.tousimis.com/critical_point_dryers/detail.html?Pid=8780C
Critical point dryer with wafer holders that allow automatic anti stiction processing up to 5 pieces of either 100mm, 75mm, 50mm wafers or 10mm square die per process run. All internal surfaces are inert to CO2 and ultra pure alcohols.
Proper citation: Tousimis: Autosamdri 815B Critical Point Dryer (RRID:SCR_018642) Copy
http://www.labwrench.com/?equipment.view/equipmentNo/9101/Wyatt-Technology/DynaPro-Plate-Reader-II/
Plate reader that automates dynamic light scattering measurements on macromolecular and nanoparticle samples in situ in 96, 384, or 1536 well microplates. It screens for particle size, thermal stability, aggregation temperature tonset, colloidal stability via diffusion interaction parameter kD or D1, and viscosity of protein solutions.
Proper citation: Wyatt: Dynapro II Plate Reader (RRID:SCR_018648) Copy
https://www.zeiss.com/microscopy/us/products/laser-microdissection/microtweezers.html
Optical tweezers system for contact free cell manipulation as well as to trap, move, and sort microscopic particles, sort live cells, organelles, and other large biomolecules.
Proper citation: Zeiss: PALM MicroTweezers (RRID:SCR_018647) Copy
https://www.unh.edu/research/transmission-electron-microscope-tem
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on April 12, 2024. Transmission electron research microscope with accelerating voltages of 120 and 200kV and has magnification from 80X to 1,000,000X with resolution line of 0.12nm.
Proper citation: Zeiss: 922 Transmission Electron Microscope (RRID:SCR_018645) Copy
https://www.leica-microsystems.com/products/light-microscopes/p/leica-dm5500-b/
Fluorescence microscope capable of contrast microscopy and has ability for fully automated Differential Interference Contrast techniques. This product has been archived and replaced with the Leica DM4 B and DM6 B microscopes.
Proper citation: Leica: DM5500 B Automated Upright Microscope System (RRID:SCR_018896) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the T1D Resources search. From here you can search through a compilation of resources used by T1D and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that T1D has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on T1D then you can log in from here to get additional features in T1D such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into T1D you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within T1D that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.