Automated cell sorter that has microfluidics sorting chip integrated with six fluorescence detectors and up to four collinear excitation lasers of 488 nm, 405 nm, 561 nm and 638 nm.
Proper citation: Sony biotechnology: SH800Z Cell Sorter (RRID:SCR_018635) Copy
Siemens Dade Behring BN II Nephelometer is leading fully automated system for plasma protein determinations. BN II systems offer advanced nephelometric technology that provides performance in plasma protein analysis. This instrument's menu covers assays, which support various clinical tests including cardiac risk assessment, kidney diseases and nutritional assessment. markers such as Cystatin C and Carbohydrate-Deficient Transferrin (CDT) are also supported. Other features of the Dade Behring BN II Nephelometer include rapid processing, easy operation and random-access mode. The nephelometer also permits users to put up to 100 samples on board, making it best for mid to high-volume processing.
Proper citation: Siemens: Dade Behring BNII Nephelometer System (RRID:SCR_018634) Copy
https://assets.thermofisher.com/TFS-Assets/LED/Specification-Sheets/Hydra_II_Spec_Sheet_FINAL.pdf
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on February 22,2024. Bench top 96 or 384 channel liquid handler capable of automating pipetting tasks, including low volume and viscous sample transfers. It utilizes syringe based technology to dispense solutions.
Proper citation: Thermo Fisher: Hydra II Microdispenser (RRID:SCR_018638) Copy
https://www.physicsforums.com/attachments/wh-ifu-minc-2_v2-pdf.41467/
Benchtop incubator microprocessor controlled, gassed, humidified, incubator intended for use in cell culture. It is designed to maintain temperature between 35 and 40 degrees celsius and gas flow within range of 15 to 25 ml min.
Proper citation: Cook Medical: WilliamA Cook Australia K-MINC-1000 Benchtop Incubator (RRID:SCR_018644) Copy
https://www.tousimis.com/critical_point_dryers/detail.html?Pid=8780C
Critical point dryer with wafer holders that allow automatic anti stiction processing up to 5 pieces of either 100mm, 75mm, 50mm wafers or 10mm square die per process run. All internal surfaces are inert to CO2 and ultra pure alcohols.
Proper citation: Tousimis: Autosamdri 815B Critical Point Dryer (RRID:SCR_018642) Copy
http://www.labwrench.com/?equipment.view/equipmentNo/9101/Wyatt-Technology/DynaPro-Plate-Reader-II/
Plate reader that automates dynamic light scattering measurements on macromolecular and nanoparticle samples in situ in 96, 384, or 1536 well microplates. It screens for particle size, thermal stability, aggregation temperature tonset, colloidal stability via diffusion interaction parameter kD or D1, and viscosity of protein solutions.
Proper citation: Wyatt: Dynapro II Plate Reader (RRID:SCR_018648) Copy
https://www.zeiss.com/microscopy/us/products/laser-microdissection/microtweezers.html
Optical tweezers system for contact free cell manipulation as well as to trap, move, and sort microscopic particles, sort live cells, organelles, and other large biomolecules.
Proper citation: Zeiss: PALM MicroTweezers (RRID:SCR_018647) Copy
https://www.unh.edu/research/transmission-electron-microscope-tem
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on April 12, 2024. Transmission electron research microscope with accelerating voltages of 120 and 200kV and has magnification from 80X to 1,000,000X with resolution line of 0.12nm.
Proper citation: Zeiss: 922 Transmission Electron Microscope (RRID:SCR_018645) Copy
https://www.microscope.healthcare.nikon.com/products/cameras/ds-fi3
High definition color microscope camera equipped with 5.9 megapixel CMOS image sensor which enables capture of high definition images of up to 2880 x 2048 pixels. Enables various observations such as brightfield, DIC, phase contrast and fluorescence.
Proper citation: Nikon: microscope camera DS-Fi3 (RRID:SCR_018857) Copy
https://bioptechs.com/product/cooled-fcs2-cfcs2/
Cooled Focht Chamber System 2 designed for live cell imaging. Has same optical and specimen accommodations as standard FCS2 but is modified to include fluid ports in base to accommodate circulation of external refrigerant.
Proper citation: Bioptechs: CFCS2 Instrument (RRID:SCR_018742) Copy
https://www.permapure.com/scientific-emissions/products/gas-humidification/fc-series-humidifiers/
FC Series humidifier. Nafion tubing provides consistent, repeatable humidification of air and hydrogen across specified flow range, for portable, stationary, automotive and aerospace applications. Perma Pure Fuel Cell Humidifier features low pressure drop and do not require power to operate.
Proper citation: Perma Pure: Nafion Fuel Cell Humidifier (RRID:SCR_018900) Copy
Patch clamp amplifiers to minimize signal to noise ratio.
Proper citation: Molecular Devices: Axopatch 200B Patch Clamp Amplifier (RRID:SCR_018866) Copy
https://www.bioseb.com/bioseb/anglais/default/item_id=57_cat_id=2_Treadmill.php
Behavioral apparatus to study locomotion. Small animal treadmill used for forced exercise training and accurate testing of fatigue in rodents. Apparatus consists of rolling belt with adjustable speed and slope, and control Unit, enabling forced exercise training and accurate testing of fatigue in rodents.
Proper citation: BIOSEB: Treadmill (RRID:SCR_018799) Copy
https://microscopecentral.com/products/olympus-bx50-fluorescence-microscope
BX50 fluorescence microscope comes with 4 position mercury fluorescence lamphouse and power supply. Filters can be added as needed. Trinocular viewing head allows you to add camera to this system.
Proper citation: Olympus: BX50 microscope (RRID:SCR_018838) Copy
Multipurpose microelectrode amplifier contains two microelectrode amplifiers ME1 and ME2. These amplifiers may be independently used for intracellular and extracellular voltage recording with simultaneous current passing, or for recording with ion sensitive electrodes.
Proper citation: Molecular Devices: Axoprobe 1A microelectrode amplifier (RRID:SCR_018841) Copy
Bench-top microwell plate based image cytometer for adherent and suspension cells.
Proper citation: Revvity: Celigo Imaging Cytometer (RRID:SCR_018808) Copy
https://www.leica-microsystems.com/products/light-microscopes/p/leica-dm5500-b/
Fluorescence microscope capable of contrast microscopy and has ability for fully automated Differential Interference Contrast techniques. This product has been archived and replaced with the Leica DM4 B and DM6 B microscopes.
Proper citation: Leica: DM5500 B Automated Upright Microscope System (RRID:SCR_018896) Copy
https://www.perkinelmer.com/lab-solutions/resources/docs/BRO_Operetta_CLS_FINAL.pdf
High content image acquisition instrument. Automatic cell imaging system designed for quantitative cellular analysis of fixed or live cells. Contains sCMOS camera that provides large field of view and high resolution image capture.
Proper citation: Perkin Elmer: Operetta CLS (RRID:SCR_018810) Copy
https://plexon.com/products/plexstim-electrical-stimulator-2-system/
Programmable constant current stimulator system with 16 channels.
Proper citation: Plexon: PlexStim Electrical Stimulator System (RRID:SCR_018890) Copy
https://www.thomasrecording.com/40mm-mem
Driver system for electrode wires or linear electrode arrays. Microdrive system for extracellular recordings by Thomas RECORDING GmbH. Can be used with different conventional extracellular recording electrodes and preamplifier systems. MEM System is adapted to special requirements e.g. MEM holder is customized so that it fits to your stereotaxic instrument.
Proper citation: Trec: Thomas Motorized Electrode Manipulator (RRID:SCR_018782) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the T1D Resources search. From here you can search through a compilation of resources used by T1D and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that T1D has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on T1D then you can log in from here to get additional features in T1D such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into T1D you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within T1D that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.