https://www.leicabiosystems.com/histology-equipment/microtomes/leica-rm2125-rts/
Manual rotary microtome that sections tissue samples. Features include precise feed mechanism, powerBase that ensures stable operation for vibration-free sectioning, advanced knife holder and specimen clamp securely align cutting edge to block, user-selectable coarse feed wheel turn direction and retraction functions, hand wheel, in-built safety guards and rounded shape with arm rests for fatigue-free sectioning,quick-exchange specimen clamp and orientation system for object head allow rapid set up for any block, and two trim steps.
Proper citation: Leica: RM2125 RTS Manual Microtome (RRID:SCR_018040) Copy
https://www.thermofisher.com/order/catalog/product/313001R#/313001R
Genetic analyzer can run sequencing and fragment analysis applications including microsatellite analysis, AFLP, LOH, SNP validation, and SNP screening. Maintenance time is reduced by eliminating manual syringe washing and filling with automated polymer delivery. Can increase data quality for sequencing and fragment analysis applications by longer read length, and higher resolution with shorter run times. Uses 96- or 384-well plates with four capillary array.
Proper citation: Thermo Fisher: Applied Biosystems: 3130 Genetic Analyzer (RRID:SCR_018046) Copy
https://timothyspringer.org/files/tas/files/biacore3000-instrument.pdf
Biacore 3000 processing unit is an established, label-free system for detailed studies of biomolecular interactions. The system delivers comprehensive characterization of the interaction, answers questions about the rate constants, affinity, specificity, and determines the active concentration of components. The ability to recover and transfer interaction partners directly to MALDI targets for identification and further characterization makes the system highly applicable to fast identification of unknown interactants.
Proper citation: GE: Biacore 3000 Real Time Biomolecular Interaction Analyzer (RRID:SCR_018044) Copy
Bioanalyzer system is automated electrophoresis tool that provides an analytical evaluation of various samples types in many workflows, including next generation sequencing NGS, gene expression, biopharmaceutical, and gene editing research. Digital data is provided in timely manner and delivers assessment of sizing, quantitation, integrity and purity from DNA, RNA, and proteins. Minimal sample volumes are required for accurate result, and data may be exported in many different formats.
Proper citation: Agilent: 2100 Bioanalyzer Instrument (RRID:SCR_018043) Copy
http://www.amplipex.com/products/large-scale-recording/
Multiplexed biosignal amplifier used to record neural signal by Amplipex Ltd. Related to electrophysiology experiments with multichannel extracellular recordings in freely moving rodents.
Proper citation: Amplipex: KJE-1001 amplifier (RRID:SCR_018017) Copy
http://neuronexus.com/wp-content/uploads/2018/09/nDrive_UserManual.pdf
Microdrive for chronic implantation of neural probe by NeuroNexus.
Proper citation: NeuroNexus: nDrive (RRID:SCR_018019) Copy
http://www.thunderbiosci.co.kr/wp-content/uploads/2017/07/Apollo-324_brochure.pdf
Compact benchtop platform that enables rapid and full walk-away automation of next generation sequencing applications. Paired with PrepX reagents, Apollo 324 line offers complete sample-toanswer solution for NGS library prep. Apollo 324 automated protocols and PrepX reagent kits combine liquid handling and proven chemistries to produce high quality libraries for all major NGS platforms. System provides complete, walkaway solution using validated protocols and chemistries that produce consistent libraries for DNA-seq, RNA-seq, and ChIP-seq applications.
Proper citation: Wafergen: Apollo 324 NGS Library Prep (RRID:SCR_018027) Copy
https://www.selectscience.net/products/gel-logic-212-pro/?prodID=83511#tab-2
Automated gel imaging system for imaging fluorescence or colorimetric data in sample formats such as gels (DNA/Coomassie/Silver stain) membranes, and 96 well plates. Features include autofocusing and directed autoexposure.
Proper citation: Select Science: Carestream Gel Logic 212 PRO Imaging System (RRID:SCR_018029) Copy
Stimulator allows computer control of stimulus amplitude and timing parameters. Designed to speed up and enhance human peripheral nerve diagnostics by facilitating semi-automated nerve excitability tests. It also has roles in wider aspects of clinical neurophysiology research, including psychological, vestibular system and nociceptive testing. CE marked medical device under European Medical Device Regulation.
Proper citation: Digimeter: DS5 Isolated Bipolar Current Stimulator (RRID:SCR_018001) Copy
https://www.bio-rad.com/en-us/product/cfx96-touch-real-time-pcr-detection-system?ID=LJB1YU15
Real Time PCR detection system that combines optical technology with temperature control. Six channel, five colors and one FRET channel, real-time PCR instrument for singlexplex or multiplex reactions. Quickly set up runs and monitor amplification traces in real time on integrated LCD touch screen, or use included CFX Maestro Software to design experiment and analyze results from connected computer.
Proper citation: Bio-Rad: CFX96 Real-Time PCR Detection System (RRID:SCR_018064) Copy
https://www.selectscience.net/products/zeiss-lsm-710-for-fluorescence-imaging/?prodID=84549#tab-2
Inverted microscope that enables confocal microscopy in cell and developmental biology.
Proper citation: Zeiss: LSM 710 Confocal Inverted Microscope (RRID:SCR_018063) Copy
https://www.biocompare.com/Product-Reviews/41153-LSM-510-META-From-Zeiss/
Versatile laser scanning confocal microscope system that is available in both upright or inverted format. Equipped with ICS-Optics. Selection of dry, water immersion and oil immersion objectives are available. ICS-Optics are infinity color corrected.
Proper citation: Zeiss: LSM 510 Confocal Microscope (RRID:SCR_018062) Copy
https://biospherix.com/products/c-chamber
Culture chamber for cell culture by BioSpherix. Functionalized by gas controllers for all bioactive gases, e.g. O2, CO2, CO, NO, etc. Made of clear polycarbonate. Magnetic seal door. Temperature is controlled. Combines with ProOx 110, ProCO2, ProOx C21, OxyCycler Series.
Proper citation: BioSpherix: C-Chamber (RRID:SCR_018189) Copy
Free online archive and distribution server for complete but unpublished manuscripts in the medical, clinical, and related health sciences. Preprints are preliminary reports of work that have not been certified by peer review. They should not be relied on to guide clinical practice or health related behavior and should not be reported in news media as established information. Research articles, systematic reviews and meta analyses, clinical research design protocols and data articles may be posted.
Proper citation: medRxiv (RRID:SCR_018222) Copy
https://www.sonybiotechnology.com/us/instruments/sh800s-cell-sorter/
Benchtop cell sorter that sorts wide range of cell sizes for many applications using microfluidic sorting chips. Integrated with comprehensive fluidics controls and advanced automation for set-up, acquisition, sort and analysis. System software supports sorting into tubes and 96- and 384-well plates. Software generates FCS 3.0 and FCS 3.1 files that can be exported to third party analysis tools. For non-clinical research use only. For applications in which cross-contamination is concern, optional e-beam sterilized consumables can be used to replace sample line and sorting chip. Optional class A2 Level II biosafety cabinet provides protection for personnel and products. Biosafety cabinet meets international standards.Optical design offers up to four collinear excitation lasers (488 nm, 405nm, 561nm and 638nm) and six fluorescence detectors. The six free-form PMTs enable detection of fluorescence signals from any laser based on filter selection.
Proper citation: Sony biotechnology: SH800S Cell Sorter (RRID:SCR_018066) Copy
https://www.mizarimaging.com/wp-content/uploads/2018/11/Tilt-Datasheet-3.pdf
Modular light sheet illumination system designed to image living samples with minimal photobleaching or phototoxicity by Mizar Imaging. Enables high spatial and temporal resolution light sheet imaging to be added to existing or new microscope system.
Proper citation: Mizar Imaging: Tilt High Resolution Light Sheet Imaging System (RRID:SCR_018156) Copy
https://s2genomics.com/singulator-100/
Singulator to automate tissue preparation for single cell and single nucleus analyses. Bench top Singulator System and single use cartridge enable tissue dissociations into singulated cells or nuclei suspensions.
Proper citation: S2 Genomics: Singulator 100 Automated Single Cell Prep Automated System (RRID:SCR_018155) Copy
https://www.yxlon.de/en/products/x-ray-and-ct-inspection-systems/yxlon-ff35-ct
Computed tomography system designed to achieve precise inspection results for wide range of applications by YXLON. Available in single or dual tube configuration, it is perfect for very small to medium sized parts inspection in automotive, electronics, aviation, and material science industries.
Proper citation: YXLON: FF35 CT (RRID:SCR_018208) Copy
Swinging bucket benchtop centrifuge. Eppendorf 5920 R refrigerated centrifuge.
Proper citation: Eppendorf: 5920R centrifuge (RRID:SCR_018092) Copy
https://www.beckman.com/liquid-handlers/biomek-i7/b87585
Liquid handling instrument designed to optimize dependability and walk-away time. Biomek i7 Hybrid with enclosure has up to 45 deck positions and includes both Multichannel and Span-8 pipette heads in enclosed work space.
Proper citation: Beckman Coulter: Biomek i7 Hybrid Automated Workstation (RRID:SCR_018094) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the T1D Resources search. From here you can search through a compilation of resources used by T1D and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that T1D has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on T1D then you can log in from here to get additional features in T1D such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into T1D you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within T1D that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.