Searching across hundreds of databases

Our searching services are busy right now. Your search will reload in five seconds.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

A human post-mortem brain model for the standardization of multi-centre MRI studies.

NeuroImage | 2015

Multi-centre MRI studies of the brain are essential for enrolling large and diverse patient cohorts, as required for the investigation of heterogeneous neurological and psychiatric diseases. However, the multi-site comparison of standard MRI data sets that are weighted with respect to tissue parameters such as the relaxation times (T1, T2) and proton density (PD) may be problematic, as signal intensities and image contrasts depend on site-specific details such as the sequences used, imaging parameters, and sensitivity profiles of the radiofrequency (RF) coils. Water or gel phantoms are frequently used for long-term and/or inter-site quality assessment. However, these phantoms hardly mimic the structure, shape, size or tissue distribution of the human brain. The goals of this study were: (1) to validate the long-term stability of a human post-mortem brain phantom, performing quantitative mapping of T1, T2, and PD, and the magnetization transfer ratio (MTR) over a period of 18months; (2) to acquire and analyse data for this phantom and the brain of a healthy control (HC) in a multi-centre study for MRI protocol standardization in four centres, while conducting a voxel-wise as well as whole brain grey (GM) and white matter (WM) tissue volume comparison. MTR, T2, and the quotient of PD in WM and GM were stable in the post-mortem brain with no significant changes. T1 was found to decrease from 267/236ms (GM/WM) to 234/216ms between 5 and 17weeks post embedment, stabilizing during an 18-month period following the first scan at about 215/190ms. The volumetric measures, based on T1-weighted MP-RAGE images obtained at all participating centres, revealed inter- and intra-centre variations in the evaluated GM and WM volumes that displayed similar trends in both the post-mortem brain as well as the HC. At a confidence level of 95%, brain regions such as the brainstem, deep GM structures as well as boundaries between GM and WM tissues were found to be less reproducible than other brain regions in all participating centres. The results demonstrate that a post-mortem brain phantom may be used as a reliable tool for multi-centre MR studies.

Pubmed ID: 25595502 RIS Download

Research resources used in this publication

None found

Additional research tools detected in this publication

Antibodies used in this publication

None found

Associated grants

None

Publication data is provided by the National Library of Medicine ® and PubMed ®. Data is retrieved from PubMed ® on a weekly schedule. For terms and conditions see the National Library of Medicine Terms and Conditions.

This is a list of tools and resources that we have found mentioned in this publication.


FSL (tool)

RRID:SCR_002823

Software library of image analysis and statistical tools for fMRI, MRI and DTI brain imaging data. Include registration, atlases, diffusion MRI tools for parameter reconstruction and probabilistic taractography, and viewer. Several brain atlases, integrated into FSLView and Featquery, allow viewing of structural and cytoarchitectonic standard space labels and probability maps for cortical and subcortical structures and white matter tracts. Includes Harvard-Oxford cortical and subcortical structural atlases, Julich histological atlas, JHU DTI-based white-matter atlases, Oxford thalamic connectivity atlas, Talairach atlas, MNI structural atlas, and Cerebellum atlas.

View all literature mentions

SPM (tool)

RRID:SCR_007037

Software package for analysis of brain imaging data sequences. Sequences can be a series of images from different cohorts, or time-series from same subject. Current release is designed for analysis of fMRI, PET, SPECT, EEG and MEG.

View all literature mentions